Assessment of test duration effect in indoor radon measurement by Monte Carlo simulations.

نویسندگان

  • Jing Chen
  • Deborah Moir
چکیده

To better understand the effect of various test durations on indoor radon measurement results in Canada, Monte Carlo simulations were performed for test durations of 1 month (30 d), 2 months (61 d), 3 months (91 d) and 6 months (183 d). For each of the specified test durations, a total of 1500 Monte Carlo simulations were performed. Each simulation was compared with the result of a 1-y measurement. On average, the radon concentration estimated from a 30-d test differed by about ±22 % from the value of a 1-y measurement. The difference reduced to about ±17 % for a 61-d test, ±14 % for a 91-d test and ±9 % for a half-year test. Health Canada's recommendation of a 3-month radon test performed during the heating season resulted in an estimated radon concentration, on average, ∼20 % higher than the value determined from a 1-y measurement. This ensures a conservative estimate of the annual average radon concentration, as there is some risk at any radon level. Therefore, to avoid an underestimation of radon exposure and to ensure appropriate levels of precision and accuracy are met, the results from this study suggest that a radon measurement duration of 3 months or longer during the heating season (from October through to April) is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte-Carlo Calculation of Radon Absorbed Dose in Optical Fiber as a Novel Method in Dosimetry and Radon Measurement

Introduction Radon is a colorless and tasteless gas which exists in most soils. It is a substance that poses a potential risk for lung cancer in case a person is exposed to high levels over long periods of time. The Environmental Protection Agency (EPA) estimates that 90% of lung cancers per year are caused by radon. The aim of this paper is to estimate the absorbed doses of 222Rn by MCNPX simu...

متن کامل

Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...

متن کامل

Absorbed Dose Assessment from Short-Lived Radionuclides of Radon (222Rn) Decay Chain in Lung Tissue: A Monte Carlo Study

Introduction: Internal exposure to radon gas progeny can lead to serious biologic damages to the lung tissue. The aim of this study was to evaluate the absorbed dose by lung tissue due to the exposure from short-lived radioactive products of radon (222Rn) decay using Monte Carlo simulation. Material and Methods: A lung equivalent p...

متن کامل

The Monte Carlo Assessment of Photon Organ Doses from 222Rn Progeny in Adult ORNL Phantom

Introduction The potential hazards posed by exposure to radiation from radon have been of great concern worldwide, since it is especially associated with increased risk of lung cancer. Some radioisotopes of radon progeny deposited in the human lungs emit β particles followed by the γ rays. While γ rays are comparatively less damaging to the respiratory system than α and β particles, it is the p...

متن کامل

Stochastic Assessment of Voltage Sags in Distribution Networks

This paper compares fault position and Monte Carlo methods as the most common methods in stochastic assessment of voltage sags. To compare their abilities, symmetrical and unsymmetrical faults with different probability distribution of fault positions along the lines are applied in a test system. The voltage sag magnitude in different nodes of test system is calculated. The problem with the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 150 2  شماره 

صفحات  -

تاریخ انتشار 2012