Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study

نویسندگان

  • De-Sheng Zhu
  • Jue Fu
  • Yi Zhang
  • Chong Xie
  • Xiao-Qing Wang
  • Yue Zhang
  • Jie Yang
  • Shi-Xu Li
  • Xiao-Bei Liu
  • Zhi-Wen Wan
  • Qiang Dong
  • Yang-Tai Guan
  • Tian-wu Chen
چکیده

BACKGROUND Transverse sinus stenosis (TSS) is common among patients with cerebral venous sinus thrombosis. No previous studies have reported on double-track sign detected on axial Gd-enhanced T1WI in TSS. This study aimed to determine the sensitivity and specificity of the double-track sign in the detection of TSS. METHODS We retrospectively reviewed medical records of 383 patients with transverse sinus thrombosis (TST) and 30 patients with normal transverse sinus from 5 participating hospitals in china from January 2008 to June 2014. 167 feasible transverse sinuses included in this study were categorized into TSS (n = 76), transverse sinus occlusion (TSO) (n = 52) and transverse sinus normal (TSN) groups (n = 39) according to imaging diagnosis on digital subtraction angiography (DSA) or magnetic resonance venography (MRV). Double-track sign on axial Gd-enhanced T1WI was compared among the three groups. Sensitivity and specificity of double-track sign in detection of TSS were calculated, with final imaging diagnosis of TSS on DSA or MRV as the reference standard. RESULTS Of 383 patients with TST recruited over a 6.5-year period, 128 patients were enrolled in the study, 255 patients were excluded because of insufficient clinical data, imaging finding and delay time, and 30 matched patients with normal transverse sinus were enrolled in the control group. Therefore, double-track sign assessment was conducted in 167 available transverse sinuses of 158 patients. Of the 76 sinuses in TSS group, 51 had double-track sign. Of the other 91 sinuses in TSO and TSN groups, 3 had a false-positive double-track sign. Thus, double-track sign on axial Gd-enhanced T1WI was 67.1% (95% CI 55.3-77.2) sensitive and 96.7% (95% CI 89.9-99.1) specific for detection of TSS. CONCLUSIONS The double-track sign on axial Gd-enhanced T1WI is highly specific and moderate sensitive for detection of TSS. Nevertheless, it could be a direct sign and might provide an early clue for TSS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی دقت و همبستگی سونوگرافی داپلر رنگی با آنژیوگرافی در تعیین شدت تنگی عروق کاروتید گردنی در بیماران ایسکمی مغزی

This is retrospective double-blind research, which was carried out in Imam Khomeini hospital in order to study the accuracy of color Doppler ultrasonography for detecting the site and grade of stenosis in cervical carotid artery. 40 patients with mean age of 62 years studied with color Doppler before DSA angiography. The most common sites of stenosis were left internal carotid (39.5%) and right...

متن کامل

A new ultrasound sign in the diagnosis of pediatric maxillary sinusitis

      Background: Computed tomography scans (CT scan) and X-rays are used to diagnose paediatric maxillary sinusitis. This study aimed at exploring the diagnostic value of the conventional and colour Doppler ultrasounds and their specific findings in cases of paediatric sinusitis.    Methods: A total of 60 children diagnosed with sinusitis were included in this s...

متن کامل

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

مقایسه دقت رادیوگرافی واترز با CT اسکن در تشخیص شکستگیهای ناحیه Midface

Background and Aim: In recent years, CT scan has become available as an alternative to conventional radiography. To date, the utility of Waters view in detecting midface fractures has been rarely evaluated. The aim of this study was to compare the diagnostic accuracy and reliability of Waters radiography with CT scan in detecting midface fractures. Materials and Methods: In this tests evaluatio...

متن کامل

Differentiation of transverse sinus thrombosis from congenitally atretic cerebral transverse sinus with CT.

BACKGROUND AND PURPOSE Transverse sinus thrombosis can have nonspecific clinical and radiographic signs. We hypothesized that the novel "sigmoid notch sign" (on head CT) can help differentiate transverse sinus thrombosis from a congenitally atretic sinus among individuals with absent signal in 1 transverse sinus by MR venography. METHODS We retrospectively evaluated 53 subjects with a unilate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015