Simple isocratic method for simultaneous determination of caffeine and catechins in tea products by HPLC

نویسندگان

  • Chamira Dilanka Fernando
  • Preethi Soysa
چکیده

Tea is a popular beverage almost all over the world. Many studies show that tea consumption is closely associated with positive health impact. Most of the HPLC methods used for the determination of tea constituents include gradient elution systems which involve expensive instrumentation. The objective of this study was to develop a simple, rapid precise and low cost HPLC method for the separation and quantification of catechins and caffeine in tea (Camellia sinensis). The method utilizes a phenyl column (2.1 × 150 mm) with a UV-detector (280 nm) where excellent chromatographic separation of tea components i.e. gallic acid (GA), caffeine (Caf), epicatechin (EC) and (-)-epigallocatechin gallate (EGCG) was achieved. The isocratic elution system of acetonitrile, glacial acetic acid and deionized water (8:1:91 v/v/v) at a flow rate of 0.5 mL/min was involved. This method produced excellent accuracy and precision. Within run and between run precision was less than 7.5 %. The equations for calibration curves were y = 0.117 (±0.010)x + 0.173 (±0.024), y = 0.100 (±0.003)x + 0.045 (±0.019), y = 0.016 (±0.001)x + 0.006 (±0.004), y = 0.025 (±0.001)x-0.025 (±0.007) for GA, Caf, EC and EGCG respectively. The method validation parameters prove that the method is efficient, a simple and adequate for the quantitative determination of principal components in tea samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous determination of caffeine and 8 catechins in oolong teas produced in Thailand

A simple, rapid and reliable method of high performance liquid chromatography (HPLC) was developed for the simultaneous determination of bioactive compounds in oolong teas. The optimized method consisted of the use of a C18 reversed-phase column, an isocratic elution system (2 ml/min) of water:acetonitrile (87:13) containing 0.05% trifluoroacetic acid and the detection wavelength of 210 nm. The...

متن کامل

Automated in-tube solid phase microextraction coupled with HPLC-ES-MS for the determination of catechins and caffeine in tea.

A polypyrrole (PPY) coated capillary and several commercially available capillaries (capillary GC columns) were used to evaluate their extraction efficiencies for catechins and caffeine. Compared with commercial capillaries that were currently used for in-tube solid phase microextraction (SPME), the PPY coated capillary showed better extraction efficiency for all of the compounds studied. Elect...

متن کامل

Simultaneous Quantitation of Theophylline and Guaifenesin in Syrup by HPLC, Derivative and Derivative Ratio Spectrophotometry for Quality Control Purposes

The aim of the present work was to develop a simple and rapid method for determination of theophylline (THP) and guaifenesin (GU) in syrup without involving any preparation operations like separation or masking. A HPLC and two spectrophotometric methods based on the derivation of the main spectra are described for the determination of THP and GU in combined pharmaceutical syrup form. The first ...

متن کامل

Simultaneous Chloramphenicol and Florfenicol Determination by A Validated DLLME-HPLC-UV Method in Pasteurized Milk

The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 µg/L with correlation coefficients > 0....

متن کامل

Simultaneous Chloramphenicol and Florfenicol Determination by A Validated DLLME-HPLC-UV Method in Pasteurized Milk

The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 µg/L with correlation coefficients > 0....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016