Investigation of the location effect of external markers in respiratory‐gated radiotherapy
نویسندگان
چکیده
PURPOSE To investigate the effect of the marker placement on the correlation relationship between the motions of external markers and the internal target under different breathing patterns for several lung cancer patients. METHOD AND MATERIAL To monitor and record simultaneous motions of internal target and associated surrogate markers during respiratory gated radiotherapy, an infrared camera system synchronized with a medical simulator was installed in our institute. Multiple external markers were placed on the patients' chest wall with proper geometrical arrangement in closely monitoring the motion of skin near tumor. The motion signals of three breathing sessions (free breathing, breath-holding, and free breathing after breath-holding) were recorded and the quality of correlation between them was analyzed. For a single marker motion, its correlation with the internal target was analyzed using cross-covariance function. For the multiple markers, their correlation with the internal target was analyzed based on additive model. RESULT Seven patients undergoing radiotherapy with right upper or middle lobe lesions were enrolled in this study. Statistic analysis based on the internal-external motion signals shows that the effect of marker location on the quality of its correlation with the internal target is varied from patient to patient. There was no specific marker location where consistently demonstrated superior quality of correlation with the internal target motion over three breathing sessions for all patients. As the composite surrogate signal which was generated from the motions of multiple external markers was used to correlate the internal target motion, significant improvement of the quality of correlation was achieved. CONCLUSION The correlation of external marker to the internal target could be influenced by several factors such as patient population, marker locations, and breathing patterns, considerably. The quality of correlation and predictability to the internal target furnished by a single external marker is inferior to that of the composite signal generated from multiple external markers. The use of composite signal shows great potential in improving the predictability of internal target motion and presents an effective way to track tumor more accurately.
منابع مشابه
Investigation of lung normal tissue doses in lung tumors radiation therapy using both gated and conventional radiotherapy
Introduction: In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the clinical target volume (CTV). With the margin increasing, a larger volume of normal tissue will be exposed to high-dose. In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), u...
متن کاملExtraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study
Background: Since tumors located in thorax region of body mainly move due to respiration, in the modern radiotherapy, there have been many attempts such as; external markers, strain gage and spirometer represent for monitoring patients’ breathing signal. With the advent of fluoroscopy technique, indirect methods were proposed as an alternative approach to extract patients’ breathing signals...
متن کاملA quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates
Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...
متن کاملInvestigation of the dose enhancement effect of spherical bismuth oxide nanoparticles in external beam radiotherapy
Introduction: External radiotherapy is the most common method of radiotherapy which the most important problem associated with is that there is no difference between healthy and tumor tissues in dose absorption. One way to differentiate the dose sensitivity is to use metal-based nanoparticles. Bismuth oxide nanoparticles are good candidates for cancer radiotherapy. In this study, we investigate...
متن کاملبررسی دز رسیده به بافت سالم ریه در پرتودرمانی تومورهای ریوی به دو روش پرتودرمانی گیتد و معمولی
In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the CTV. With the margin increasing, a larger volume of normal tissue will be exposed to high-dose. In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), using the NCAT digital phantom. Different series of CT im...