A View-sharing Compressed Sensing Technique for 3D Catheter Visualization from Bi-planar Views

نویسندگان

  • C. O. Schirra
  • S. Weiss
  • S. Krueger
  • R. Razavi
  • S. Kozerke
  • T. Schaeffter
چکیده

Introduction Fast visualization of catheters is indispensable for MR-guided interventions. Recently, Compressed Sensing (CS) was introduced as a method for accelerated 3D catheter visualization exploiting the inherent sparsity of the given signal acquired with an active device [1]. However, the frame rate of the 3D CS technique is still too slow (i.e. 3 frames/s) to capture fast changes of the catheter (e.g. flipping). As known from X-ray fluoroscopy, the 3D shape of a device can be determined from two bi-planar views [2]. We propose a new method based on bi-planar imaging using two perpendicular 2D projection views. For fast MR-imaging of the two projection views a randomized view-sharing (VS) 1D phase encoding scheme was applied allowing for image reconstruction of the catheter shape using CS. Furthermore, the VS scheme allows for simultaneous acquisition of anatomical images from which organ motion can be detected. A novel catheter design is used that combines a micro-coil for tiptacking and a single-loop antenna for visualization of the catheter shape. The method was assessed in a simulation and its feasibility was tested in an in-vivo pig experiment. Materials and Methods Catheter Design: The active catheter was constructed with a small solenoidal tip coil connected in series with a 10cm single loop antenna followed by a safe transmission line [3]. This combination allows simultaneous tip tracking and shape visualization and prevents RF coupling and associated heating. Catheter Imaging: Two orthogonal projection images (Fig. 2a) were obtained in an interleaved way using R-fold random VS undersampling (Fig. 2b). The excitation of a large slab for both views ensured imaging of the catheter inside the slab while maintaining the steady-state of the transversal magnetization in the volume for both views. Given the catheter design, high signal was obtained at the tip and lower while constant signal along the first 10cm of the shaft resulted from the resonant single loop. Catheter Visualization: Image reconstruction involved two steps: First the catheter tip position was calculated by determining the maximum value in the CS reconstructions in both views and reprojecting the positions in 3D (Fig. 2a). Secondly, the catheter shape was reconstructed using a penalized CS reconstruction [1] in both views. On these images, a 2D to 3D curve was performed (Fig. 2a) using the tip position and the length of the catheter (10cm) as constraints. VS reconstruction was used to obtain anatomical projection images at R-fold reduced frame rate. Experiments: All data were acquired on a 1.5T system (Philips Healthcare, Best, The Netherlands) using a T1-weighted TFE sequence. In order to test the accuracy of the catheter visualization 18 sets of fully sampled views of the catheter were acquired from different angles (increment 10°). This allowed the reconstruction of high quality images as reference in order to compare CS reconstruction. Flipping of the catheter with different speeds was simulated from fully sampled images (Fig. 3b) and CS reconstructions (Fig.3c) were compared to VS reconstruction (Fig.3a), both from 5-fold undersampling. Reconstruction quality was assessed by measuring the cross-correlation (CC) between the reconstructions and the original images (Fig. 3d) and measuring the sidelobe-topeak ratio (SPR) of the tip (Fig.3e). In-vivo, the method was tested during cardiac catheterization of a 40kg pig. The catheter was visualized using the described method (single-shot TFE, TR/TE/flip 1.77/0.87/5°, acquisition matrix 450x250 mm2, slice thickness 250 mm, BW 2231 Hz, 4-fold undersampling). The reconstructed catheter outline was then displayed on a pre-acquired highresolution roadmap (Fig. 4a). Furthermore, data simultaneously measured with the imaging coil was used to extract respiratory motion (Fig. 4c) from anatomical projection images (Fig. 4b). Results CS reconstruction (Fig. 3c) showed significant improvement of image quality in comparison to VS reconstruction (Fig. 3a). With a subsequent curve fit, the complete catheter shape could be reconstructed using the tracked tip position and the known length of the line as constraints. Figure 3 shows improved image quality of CS reconstruction, whereas VS reconstruction results in significantly lower CC and a higher SPR due to residual aliasing and blurring. In the in-vivo experiment, the catheter was successfully traced (Fig. 4a) and respiratory motion determined from the coronal anatomical image (Fig. 4b,c). Discussion and Conclusion The novel catheter design in combination with bi-planar imaging employing CS and VS reconstruction was shown to enable for precise tracking of the tip position and robust recovery of the catheter outline in 3D. VS reconstruction allowed for display of anatomical detail at lower frame rates and permitted extraction of respiratory motion in the in-vivo situation which may be used for motion modelling in the future[4]. With an active device in transmit/receive mode, excitation of thin slices is possible [5] which would improve anatomical imaging further. With the proposed method 3D visualization of the catheter at about 10 frames per second was achieved in-vivo. Since the performance of CS also depends on base SNR, higher frame rates are possible through base SNR improvements. In summary, the method presented holds considerable potential for improving accuracy and navigation of active interventional devices. References [1] Schirra et al., Proc. ISMRM 2008, p. 338 [4] King et al., Proc. ISMRM 2008, p. 2999 [2] Rhode et al., IEEE TMI 2005, 24:1428-40 [5] Weiss et al., Proc. ISMRM 2008 p. 283 [3] Weiss et al., MRM 2005, 54:18 (a)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D MRI-guided Passive Catheter Tracking and Visualization using HYPR-based Techniques

INTRODUCTION Catheter tracking and visualization require both good spatial and temporal resolution. Achieving simultaneously both high temporal and spatial resolution is extremely difficult with current methods that use Cartesian k-space acquisition employing phase encoding. To date, passive device tracking and visualization techniques have typically been limited to two dimensions [1-2]. This i...

متن کامل

Accelerated 4D flow imaging using randomly undersampled echo planer imaging with compressed-sensing reconstruction

Introduction 2D phase contrast (PC) CMR is currently the standard clinical imaging sequence for evaluation of blood flow [1]. Recently, 3D time-resolved PC CMR (4D-PC) has been used for quantification and visualization of blood flow in all three directions of a volume [2]. However, such acquisitions require long scan times (often 10-20 minutes), which reduces its clinical feasibility and leads ...

متن کامل

Clinical evaluation of the respiratory mechanics using accelerated 3D dynamic free breathing MRI reconstruction

Three-dimensional dynamic MRI (3D-DMRI) is a promising method to analyze respiratory mechanics. However, current 3D DMRI implementations o er limited temporal, spatial resolution and volume coverage. In this work we demonstrate the feasibility of three compressed sensing reconstruction methods along with view-sharing method with clinical evaluation on 8 healthy subjects by expert radiologists. ...

متن کامل

2094 3 D visualization of active catheters using compressed sensing

Introduction A crucial requirement in MR-guided interventions is the visualization of catheter devices in real-time. Common tracking techniques rely either on image projections to localize the catheter tip [1] or on single slice imaging [2] to capture the extent of the catheter in parts. True threedimensional visualisation of the full length of catheter devices has hitherto been impossible give...

متن کامل

A Hybrid Method for Segmentation and Visualization of Teeth in Multi-Slice CT scan Images

Introduction: Various computer assisted medical procedures such as dental implant, orthodontic planning, face, jaw and cosmetic surgeries require automatic quantification and volumetric visualization of teeth. In this regard, segmentation is a major step. Material and Methods: In this paper, inspired by our previous experiences and considering the anatomical knowledge of teeth and jaws, we prop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008