Vector analysis of corneal and refractive astigmatism changes following toric pseudophakic and toric phakic IOL implantation.

نویسندگان

  • Nienke Visser
  • Tos T J M Berendschot
  • Noël J C Bauer
  • Rudy M M A Nuijts
چکیده

PURPOSE To determine the efficacy of the astigmatism correction following toric intraocular lens (IOL) and toric phakic IOL (pIOL) implantation in eyes with no previous ocular surgery and in postkeratoplasty (PKP) eyes. In addition, changes in corneal astigmatism were determined. METHODS Astigmatism was analyzed in 35 eyes with an AcrySof toric IOL, 35 eyes with an Artiflex toric pIOL, 50 eyes with an Artisan toric pIOL, and 40 PKP eyes with an Artisan toric pIOL. Refractive astigmatism was analyzed by using Alpins method. Surgically induced corneal astigmatism (SICA) was determined following a superior 2.2-mm, 3.4-mm, or 5.4-mm incision. Follow-up was 12 months. RESULTS Following toric IOL implantation, the index of success was 0.14 and overall residual astigmatism, 0.37 diopter (D). Following toric pIOL implantation, the index of success was 0.32 (Artiflex) and 0.18 (Artisan), and overall residual astigmatism was approximately 0.60 D. In PKP eyes, Artisan pIOLs resulted in an index of success of 0.28 and overall residual astigmatism of 1.56 D. The SICA, following 2.2-mm, 3.4-mm, 5.4-mm (normal eyes), and 5.4-mm (PKP eyes) incisions, was -0.25 ± 0.42 D (P = 0.108), -0.31 ± 0.43 D (P < 0.001), -0.48 ± 0.55 D (P < 0.001), and -0.49 ± 1.48 D (P = 0.035), respectively. CONCLUSIONS Toric IOLs and pIOLs provide an effective astigmatism correction. Incorporating the SICA into the toric IOL power calculation may further increase their effectiveness. Therefore, incorporation of 0 D, -0.30 D, or -0.50 D of SICA for a 2.2-, 3.4-, or 5.4-mm superior incision, respectively, is recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cataract Surgery in Eyes with Low Corneal Astigmatism: Implantation of the Acrysof IQ Toric SN6AT2 Intraocular Lens

PURPOSE To assess the refractive and visual outcomes following cataract surgery and implantation of the AcrySof IQ Toric SN6AT2 intraolcular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients with low corneal astigmatism. METHODS This study is a retrospective, consecutive, single surgeon series of 98 eyes of 88 patients (with low preoperative corneal astigmatism) undergoin...

متن کامل

Implantation of a toric phakic intraocular lens to correct high corneal astigmatism in a patient with bilateral marginal corneal degeneration.

We present a patient with marginal corneal degeneration and corneal astigmatism of more than 10.0 diopters (D). A toric phakic intraocular lens (IOL) of 7.0 D cylindrical power was implanted in both eyes to correct the high astigmatism. An uncorrected visual acuity of 20/40 was achieved in both eyes, and the best corrected visual acuity improved by 4 Snellen lines to 20/20 in both eyes. Refract...

متن کامل

Toric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial.

IMPORTANCE Spectacle independence is becoming increasingly important in cataract surgery. Not correcting corneal astigmatism at the time of cataract surgery will fail to achieve spectacle independency in 20% to 30% of patients. OBJECTIVE To compare bilateral aspherical toric with bilateral aspherical control intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism...

متن کامل

AcrySof IQ toric IOL implantation combined with limbal relaxing incision during cataract surgery for eyes with astigmatism >2.50 D.

PURPOSE To evaluate the effectiveness of toric intraocular lens (IOL) implantation combined with limbal relaxing incision (LRI) for patients with high-amplitude astigmatism. METHODS This single-center, prospective study evaluated 22 eyes of 19 patients with cataract and >2.50 diopters (D) astigmatism that underwent bimanual micro-phacoemulsification cataract surgery and toric IOL implantation...

متن کامل

Refractive and visual outcome of toric intraocular lens implantation following cataract surgery.

PURPOSE To evaluate the refractive and visual outcome of toric IOL implantation for correction of pre-existing corneal astigmatism following cataract surgery. MATERIALS AND METHODS In this retrospective study, 56 eyes of 30 patients who underwent implantation of toric IOL following regular phacoemulsification were divided into two groups based on the types of toric IOL implanted: group 1 pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 4  شماره 

صفحات  -

تاریخ انتشار 2012