Influence of therapeutic ultrasound on the biomechanical characteristics of the skin

نویسندگان

  • Lígia Brancalion Catapani
  • Adriana da Costa Gonçalves
  • Nathalia Morano Candeloro
  • Lídia Aparecida Rossi
  • Elaine Caldeira de Oliveira Guirro
چکیده

BACKGROUND Skin function is dependent on its biomechanical characteristics, resistance, malleability, and elasticity. Therapeutic ultrasound may increase cutaneous malleability thus and optimize the rehabilitation process on specific diseases. The aim of this study is to evaluate possible alterations of biomechanical characteristics of the normal skin after therapeutic ultrasound application. METHODS Thirty-one volunteers took part of the study, and the average age was 31.61 ± 8.37 years old. Biomechanical characteristics evaluation of the skin was performed with the Cutometer MPA 580 (Courage + Khazaka Electronic-Köln, Germany) of 2-mm probe hole and 500-mbar vacuum. Skin characteristics were analyzed before and after therapeutic ultrasound application, and the variables R0 (distensibility), R2 (gross elasticity), and R6 (viscoelasticity) were used for the study. Areas of therapeutic ultrasound application (continuous, 3 MHz, 1 W/cm(2) SATA) were defined at the upper limbs and standardized using a neoprene template. Sociodemographic data of volunteers were analyzed using SPSS 15.0. To analyze the distribution of the data, the Shapiro-Wilk test was used, which showed the normal distribution for R0 values, R2 and R6. For this procedure, the PROC TTEST from SAS® 9.0 software and Minitab 16 software, with significance, was set at the 0.05 level. RESULTS In relation to R0, a significant increase (p = 0.001) was observed for the distensibility, when compared to values of pre- (0.3273 mm) and immediately post- (0.3795 mm) resource application which feature a greater distensibility. Related to R2 values, a significant increase (p = .001) of the gross elasticity at pre- (0.8419) and post- (0.8884) therapeutic ultrasound application was found. CONCLUSIONS Therapeutic ultrasound promotes significant alterations of the biomechanical characteristics of the skin. TRIAL REGISTRATION ClinicalTrials.gov, 1111-1146-7342.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Therapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics

Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...

متن کامل

Histopathological and Biomechanical Study on the Effect of Aftemisia sieberi Extract on Experimental Skin Wound llealing in Rat

Objectiv e- To eval uate the effects of Artemisia sieberi extract on experimental dermal wounds healing .Design- Experimental study.Animals- 30 male Spragne-Dawly rats.Procedures- Two uniform 7 mm diameter skin defect were created on the back of each animal by skinpunch (total of 60 wounds). Then, the extract of the plant was applied once daily on half of the wounds forhistopathological and bio...

متن کامل

Low intensity ultrasound mechanical index as a parameter affecting of ability of proliferation and collagene type 1 expression of cells

Introduction: Mechanical index (MI) is used for quantifying acoustic cavitation and the relationship between acoustic pressure and the frequency. In this study, modeling of the MI was applied to provide treatment protocol and to understand the effective physical processes on reproducibility and gene expression of fibroblast cells. Skin damage can occur of burn, cuts, abrasions ...

متن کامل

Biomechanical Evaluation and Comparison of the Artificial and Natural Skin Properties Using Finite Element Method

Introduction: The self-repair process cannot occur in the skin lesions, therefore, skin replacements are used due to the formation of a scar, which resulted in the complete loss of skin. Artificial skin should have the same specifications as the natural skin. The finite element methods were used in this study to evaluate the biomechanichal properties of natural and artificial skins. Materials ...

متن کامل

بررسی اثر امواج اولتراسوند منقطع با فرکانس پایین بر تشکیل کال استخوانی تیبیا در خرگوش( ارزیابی رادیولوژیک و بیومکانیک)

Background and Objective: Application of low intensity ultrasound has been used for treatment of many diseases in medicine and has suggested for accelerating wound healing process, modifying scar tissue and relief of pain. The aim of this study was radiological and biomechanical evaluation of low-intensity pulsed ultrasound on callus formation of tibia in rabbit. Materials and Methods: In this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016