Measurement of aldosterone in human plasma by semiautomated HPLC-tandem mass spectrometry.
نویسندگان
چکیده
BACKGROUND Reliable measurement of aldosterone with less interlaboratory variation than RIA would help standardize testing for primary aldosteronism. We set out to validate a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for aldosterone in human plasma. METHODS We prepared samples (EDTA plasma, lithium heparin plasma, and serum from separator and plain clot tubes) and measured aldosterone using online HPLC-MS/MS with d(7)-aldosterone as internal standard. We also analyzed EDTA plasma samples by immunoassay. We established a reference range for HPLC-MS/MS aldosterone by analyzing blood collected midmorning from 97 normotensive seated subjects. RESULTS The linear range was 69.4-5548.0 pmol/L (2.5-200 ng/dL) (r(2) > 0.994, n = 14). Inter- and intraday analytical recovery and imprecision for quality control samples of 166.4, 1109.6, and 4161.0 pmol/L (6.0, 40.0, and 150.0 ng/dL) were 92.2%-102.0% and <6.3%, respectively (n = 5). The lower limit of quantification was 69.4 pmol/L (2.5 ng/dL), with inter- and intraday analytical recovery and imprecision of 91.4%-94.5% and <9.5% (n = 5). No interferences were observed in plasma from Addison's disease patients (n = 5). Comparison of collection tubes, using EDTA as the reference, revealed similar aldosterone results. Comparison of HPLC-MS/MS with immunoassay gave an acceptable mean bias (0.83%) but wide range (-44.8% to 39.7%) of differences. HPLC-MS/MS aldosterone concentrations in normotensive subjects ranged from <69.4 to 635.2 pmol/L (<2.5 to 22.9 ng/dL). CONCLUSIONS This first reported aldosterone method using online HPLC-MS/MS is precise across the clinically relevant range, not influenced by collection tube type, and offers semiautomated sample preparation and high throughput.
منابع مشابه
Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...
متن کاملA quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملDevelopment and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 55 6 شماره
صفحات -
تاریخ انتشار 2009