Development of ventricular fibrillation after implantation of a biventricular implantable cardioverter defibrillator: what is the mechanism?

نویسندگان

  • Diego Chemello
  • Fernando Pivatto Júnior
  • Maurício Pimentel
  • Leandro Zimerman
چکیده

Syncopal spells in heart failure patient with cardiovascular implantable electronic devices (CIED) require multiple assessments. T-wave oversensing is a well-described phenomenon that remains significant in modern implantable cardioverter defibrillators (ICD) systems. It can lead to inappropriate therapies and loss of biventricular pacing in those with cardiac resynchronization devices. Strategies to overcome this problem are important.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Impact of the implantable cardioverter-defibrillator on rehospitalizations.

UNLABELLED Patients who survive out-of-hospital ventricular tachycardia or ventricular fibrillation are at risk of sudden cardiac death and often return to hospital after initial discharge. The frequency and duration of readmittance to hospital are not well known. Thus, the purpose of this study was to evaluate the impact of the implantable cardioverter defibrillator on frequency and duration o...

متن کامل

T wave oversensing and low percentage of biventricular pacing in cardiac resynchronization therapy.

The success of cardiac resynchronization therapy (CRT) depends on a high percentage of ventricular pacing. We present the electrocardiography and electrograms of a patient who underwent an implantable cardioverter-defibrillator (ICD) with CRT implantation showing a low percentage of ventricular pacing as a result of T wave oversensing of paced QRS. The patient showed no clinical improvement. We...

متن کامل

Hyperglycemia-Induced T-Wave Oversensing as a Cause of Cardiac Resynchronization Therapy (CRT) Failure

T-wave oversensing occurs when the counter starts giving dual beeps for every cardiac cycle instead of one. This usually happens when the monitoring lead displays a tall T wave, which is also sharp. R wave sensing algorithms of the devices do not sense T wave because the slow rate of the T wave is much less than that of the R wave. But the slow rate of T waves may change with time and also beca...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017