Dimensional accuracy and retentive strength of a retrievable cement-retained implant-supported prosthesis.

نویسندگان

  • A P Randi
  • A T Hsu
  • A Verga
  • J J Kim
چکیده

The purpose of this research project was to compare the fit of a retrievable cement-retained implant-supported framework to that of a traditional wax and cast, screw-retained framework and to test the strength of the cemented restoration. Ten telescopic frameworks were luted to gold cylinders with a bis-GMA resin cement. The control group consisted of 10 frameworks fabricated with traditional wax and casting techniques directly to the gold cylinders. Frameworks were analyzed for distortion in the z-axis using scanning electron microscopy and a single screw test. Results demonstrated that the retrievable cement-retained group had a decreased gap distance and improved angular distortion (statistical significance P < .01) compared to the control group. Retentive strength measurements for the cement-retained group with a direct pull-out test revealed a mean pull-out force of 65.7 kg. Three of the 5 samples surpassed the tensile strength of the gold retaining screws (76 kg). Cement-retained restorations demonstrated superior fit in the z-axis and angular distortion compared to traditional wax and cast screw-retained frameworks. Retentive tests support a simplified technique of clinically luting telescopic implant-supported frameworks with adequate retentive strength.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Three Types of Temporary Luting Cements and Abutment Surface Sandblasting on Retentive Strength of Implant-Supported Fixed Prostheses

Background and Aim: Achieving appropriate retention and easy retrieva bility at the same time is challenging in implant-supported fixed par tial dentures (FPDs). Researchers have always been in search of a temporary cement to improve the retentive strength. The aim of this in vitro study was to evaluate the effect of three different temporary ce ments and sandblasting of the abutment surface on...

متن کامل

Comparison of the effect of implant abutment surface modifications on retention of implant-supported restoration with a polymer based cement.

BACKGROUND In cement-retained implant-supported restoration it is important to gain adequate retention of definitive restoration as well as retrievability of prosthesis. The surface of the abutment, alloy of the restoration and the type of cement used influences the retention of the restoration. There is a need to analyze the influence of surface modifications of abutments on the retentive capa...

متن کامل

Full mouth rehabilitation with retrievable metal–ceramic implant‐supported fixed prostheses for a young patient with atrophic jaws: a clinical report

Treatment of atrophic edentulous jaws with implant-supported fixed prostheses is one of the most complicated challenges in dentistry. This clinical report describes the prosthesis which consists of screw retained frameworks with individual cement retained crowns which combines the advantages of the screw retained restoration with the advantage of cement retained.

متن کامل

بررسی تاثیرخشونت سطحی اباتمنت بر میزان استحکام گیر رستوریشنهای سمان شونده متکی بر ایمپلنت با سمان موقتی

 Background and Objective: Surface roughness can increase the retention of castings by sandblast that are micro retentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement.  Materials and Methods: Thirty abutments (DIO implant- Cemented abutment,SAC 4814N(II)) were divided in three groups, first ...

متن کامل

The Effect of Compressive Cyclic Loading on the Retention of Cast Single Crowns Cemented to Implant Abutments.

PURPOSE The aim of this study was to evaluate and compare the retention strength of three cements commonly used in implant-supported prostheses before and after compressive cyclic loading. MATERIALS AND METHODS The working model consisted of five solid abutments, 7 mm in height and with a 6-degree taper, screw retained to five implant analogs secured in a rectangular block of self-curing acry...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2001