Helical computed tomography of the abdomen: evaluation of image quality using 1.0, 1.3, and 1.5 pitches.
نویسندگان
چکیده
BACKGROUND The purpose of this study was to investigate whether trained radiologists can distinguish minor differences among computed tomography (CT) images of extended helical pitches of 1.0 to 1.5. METHODS Between September 2000 and February 2001, 72 patients were randomized into 1 of 3 equal groups: helical pitches of 1.0, 1.3, and 1.5. The imaging parameters of all patients were kept constant. Twelve of the 72 patients were excluded because of various pathological conditions. In a total, 60 examinations were enrolled in the evaluation study. Three radiologists blinded to the image parameters were asked to independently evaluate 9 normal structures and overall images of 60 studies using a scale from 1 (worst) to 5 (best). RESULTS There were no statistically significant differences in evaluation of image quality among helical pitches 1.0, 1.3, and 1.5 of abdominal CT when assessing 9 normal structures and overall images independently (p > 0.05). CONCLUSIONS Abdominal CT performed with helical pitches of 1.0, 1.3, and 1.5 were equivalent in this study. With the use of a helical pitch greater than 1, clinicians can benefit from increased scan coverage in less time and with less radiation than can be achieved with standard helical pitch-1.0 protocols.
منابع مشابه
Optimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose
Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...
متن کاملAssessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels
Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...
متن کاملComparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملEvaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملAssessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain
Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...