A Comparison of the Uniformity Requirements for SPECT Image Reconstruction using FBP and OSEM Techniques
ثبت نشده
چکیده
منابع مشابه
A comparison of the uniformity requirements for SPECT image reconstruction using FBP and OSEM techniques.
OBJECTIVE Gamma camera nonuniformity can result in the presence of ring artifacts in reconstructed SPECT images. The objective of this study is to compare the relationship between ring artifact magnitude and image noise in tomographic images reconstructed using FBP and OSEM. METHODS A cylindrical phantom was filled with water and (99m)TC: Seven tomographic acquisitions were performed, with to...
متن کاملAssessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]
Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملAssessment of OSEM & FBP Reconstruction Techniques in Single Photon Emission Computed Tomography Using SPECT Phantom as Applied on Bone Scintigraphy
Filtered back projection (FBP) method and maximum likelihood expection maximization (OSEM) method are currently used for reconstruction of SPECT images in clinical studies. The aim of this work is to compare the image quality using different reconstruction techniques of a SPECT phantom as applied to bone scintigraphy. The resolution and contrast of the hot spheres were observed using a phantom ...
متن کاملImpact of reconstruction method on quantitative parameters of 99mTc-TRODAT-1 SPECT
Introduction: Quantitative evaluation is recommended to improve diagnostic ability and serial assessment of dopamine transporter (DAT) density scans. We decided to compare the ordered subsets expectation-maximization (OSEM) with filtered back-projection (FBP), and to investigate the impact of different iteration and cut-off frequencies on SBR values. Methods</stro...