Prospective clinical evaluation of 1920 Morse taper connection implants: results after 4 years of functional loading.
نویسندگان
چکیده
PURPOSE This study evaluated the survival rate and the clinical, radiographic and prosthetic success of 1920 Morse taper connection implants. MATERIAL AND METHODS One thousand nine hundred and twenty Morse taper connection implants were inserted in 689 consecutive patients, from January 2003 until December 2006. Implants were clinically and radiographically evaluated at 12, 24, 36 and 48 months after insertion (mean follow-up per implant: 25.42 months). Modified plaque index (mPI), modified sulcus bleeding index, probing depth (PD) and the distance between implant shoulder and first crestal bone-implant contact (DIB) were measured in mm. Success criteria included the absence of suppuration and clinically detectable implant mobility, PD<5 mm, DIB<1.5 mm after 12 months of functional loading and not exceeding 0.2 mm for each following year, the absence of recurrent prosthetic complications at the implant-abutment interface. Prosthetic restorations were fixed partial prostheses (364 units), single crowns (SCs: 307 units), fixed full-arch prostheses (53 units) and overdentures (67 units). RESULTS The overall cumulative implant survival rate was 97.56% (96.12% in the maxilla and 98.91% in the mandible). The cumulative implant success rate was 96.61% (95.25% in the maxilla and 98.64% in the mandible). Only a few prosthetic complications were reported (0.65% of loosening at implant-abutment interface in SCs). CONCLUSION The use of Morse taper connection implants represents a successful procedure for the rehabilitation of partially and completely edentulous arches. The absence of an implant-abutment interface (microgap) is associated with minimal crestal bone loss. The high mechanical stability significantly reduces prosthetic complications.
منابع مشابه
Prospective evaluation of 2,549 Morse taper connection implants: 1- to 6-year data.
BACKGROUND The aim of this study is to evaluate the implant survival, the implant-crown success, and the prosthetic complications of 2,549 Morse taper interference-fit connection implants. METHODS A total of 2,549 Morse taper connection implants were inserted in 893 patients from January 2003 until December 2008. At each annual recall, clinical, radiographic, and prosthetic parameters were as...
متن کاملMorse taper connection implants supporting "planned" maxillary and mandibular bar-retained overdentures: a 5-year prospective multicenter study.
OBJECTIVES In contrast to the excellent long-term outcomes described for implant-supported mandibular overdentures, less favorable long-term survival and success rates have been reported for maxillary implants supporting overdentures. The aim of this study was to evaluate the treatment outcome of "planned" bar-retained maxillary and mandibular overdentures supported by Morse taper connection im...
متن کاملPreload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review
Background To carry out a systematic literature review of the causes of preload loss of the abutment screws, of internal and external connection implants, tightened to different torque values and subjected to cyclic loading. Material and Methods A systematic search was conducted in PubMed, EMBASE, and Cochrane Library databases with reference to in vitro studies in which internal and external...
متن کاملSingle tooth replacement by Morse taper connection implants: a retrospective study of 80 implants.
The goal of this study was to provide data relative to the use of a new implant system (Mac System, Cabon, Milan, Italy) with a Morse taper implant-abutment connection for single implant restorations. The implant system is composed of an endosseous screw made of commercially pure titanium grade 2, while the abutment is titanium alloy (Ti-6Al-4V). A total of 80 single implants were placed in 69 ...
متن کاملInfluence of Connection Types and Implant Number on the Biomechanical Behavior of Mandibular Full-Arch Rehabilitation.
PURPOSE To evaluate the influence of different implant numbers and connection types on the biomechanical behavior of mandibular full-arch implant-supported rehabilitation. MATERIALS AND METHODS Computed tomography-based finite element models comprising a totally edentulous mandible and 3.8 × 13-mmdiameter implants, abutments, abutment screws, bar retaining screw, and bar were constructed. Dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oral implants research
دوره 20 3 شماره
صفحات -
تاریخ انتشار 2009