The respiratory responses of the fowl to hot climates.
نویسندگان
چکیده
Respiratory rate (f) and tidal volume (VT) have been measured at normal and at warm ambient temperatures (Ta) in adult domestic fowl by means of a whole body plethysmograph. Resting values of f = 23 +/- 9 min-1 and of VT = 25.6 +/- 0.9 ml min-1 were found. At Ta 30, 35 or 40 degrees C f increased in direct relation to the severity of the heat stress reaching a maximum values of 273 +/- 12 min-1; VT fell uniformly in all three climates to a minimum of 9.0 +/- 0.5 ml. Total ventilation (V) showed a linear relation with f during first-phase panting. Second-phase panting occurred only at Ta 40 degrees C; V increased at first but subsequently fell as the decline in f became more pronounced.
منابع مشابه
A comparative study on details of green walls in different climates
Global warming has today turned to one of the most important environmental issues due tooveruse of fossil fuels, and it needs serious attention. Since the mid-1970s, an urgent needwas therefore felt around the world to reduce the use of energy for heating and cooling inbuildings. Using green covers, especially green facades, in appropriate environmentalconditions can be regarded as a method to ...
متن کاملEvaluation of Efficacy of Razi Fowl Pox Vaccine in Comparison of Commercial Fowl Pox Vaccine in SPF Chickens by Challenge Test
Abstract Fowl pox vaccine is produced in the Razi Institute for almost half a century and has a favorable and productive yield in poultry flocks and has provided complete satisfaction to the poultry breeder. In terms of comparing the efficacy of this vaccine with imported vaccines, the following research was conducted. In this study, based on the latest protocols of European Pharmacopeia and O...
متن کاملMaking balance between optimum daylight and thermal comfort in hot-humid climates Case study: Rashidy historic mansion in Bushehr city, Iran
Day lighting is one of the important qualitative factors in housing, which is also effective on health and well-being of occupants. Extensive glass surfaces and Transparency in building facades provides good daylight quantity for interior spaces. However, this lighting system is not appropriate for climates faced with higher sunlight radiation (Such as hot-humid areas), due to overheating and d...
متن کاملArchitectural Design Optimization of School Buildings for Reduction of Energy Demand in Hot & Dry Climates of Iran
School buildings as a major part of public buildings are considered as one of the basic consumers of energy in Iran. Based on building typology and occupancy patterns, school buildings have a great potentiality for energy optimization while providing thermal comfort. This study investigates the architectural design parameters such as orientation, optimum window to wall ratio, space organization...
متن کاملOffice Buildings Glass Facades Excitation under Hot and Dry Climates: A Numerical and Experimental Study
The purpose of this research is to reviews the thermal comfort condition of full glass south view official buildings in warm and dry zones and conclusion of buildings disadvantage in thermal waste and after all presenting an ideal plan with appropriate solution. To reach to that goal first of all the effective factors on wasting energy were reviewed then the temperature testing with thermometer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of experimental biology
دوره 97 شماره
صفحات -
تاریخ انتشار 1982