Minimizing human error in radiopharmaceutical preparation and administration via a bar code-enhanced nuclear pharmacy management system.

نویسندگان

  • John L Hakala
  • Joseph C Hung
  • Elton A Mosman
چکیده

UNLABELLED The objective of this project was to ensure correct radiopharmaceutical administration through the use of a bar code system that links patient and drug profiles with on-site information management systems. This new combined system would minimize the amount of manual human manipulation, which has proven to be a primary source of error. The most common reason for dosing errors is improper patient identification when a dose is obtained from the nuclear pharmacy or when a dose is administered. A standardized electronic transfer of information from radiopharmaceutical preparation to injection will further reduce the risk of misadministration. METHODS Value stream maps showing the flow of the patient dose information, as well as potential points of human error, were developed. Next, a future-state map was created that included proposed corrections for the most common critical sites of error. Transitioning the current process to the future state will require solutions that address these sites. To optimize the future-state process, a bar code system that links the on-site radiology management system with the nuclear pharmacy management system was proposed. A bar-coded wristband connects the patient directly to the electronic information systems. RESULTS The bar code-enhanced process linking the patient dose with the electronic information reduces the number of crucial points for human error and provides a framework to ensure that the prepared dose reaches the correct patient. Although the proposed flowchart is designed for a site with an in-house central nuclear pharmacy, much of the framework could be applied by nuclear medicine facilities using unit doses. CONCLUSION An electronic connection between information management systems to allow the tracking of a radiopharmaceutical from preparation to administration can be a useful tool in preventing the mistakes that are an unfortunate reality for any facility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation, formulation and quality control of one step kit 99mTc- EDDA/HYNIC-Tyr3-Octreotide as a peptide radiopharmaceutical for imaging somatostatin receptor positive tumors [Persian]

The high expression of somatostatin receptors in many tumours, have made receptor scintigraphy with 111In-DTPA-Octreotide a widly used procedure in nuclear medicine. Despite its clinical success, some limitation and drawbacks of radiolabelling with 111In remain, especially those concerned with the cost, availability and physical decay properties of this radionuclide. 99mTc-EDDA/HYNIC-Tyr3...

متن کامل

Radiopharmaceutical regulation worldwide - The resemblances and the differences [Persian]

A Radiopharmaceutical is a radioactive compound used for the diagnosis and treatment of human diseases. Radiopharmaceuticals are among the most highly regulated materials administered to patients because they are controlled both as drugs and as radioactive substances. The use of radiopharmaceuticals for any purpose is governed by regulatory agencies in different countries all over the wor...

متن کامل

Measurement of dose equivalent of hand and eye of a nuclear medicine center technician during preparation of radiopharmaceutical containing 99mTc

Due to gamma irradiation by radioisotopes use for therapy and diagnostics proposes such as 99mTc, workers of nuclear medicine centers receives dose. Value of the dose equivalent of workers is determined using personnel dosimeters. Preparation, administration and injection of radiopharmaceutical are perfumed by technician so, the hand of technician received dose. In this paper the value of dose ...

متن کامل

Fundamental concepts of radiopharmaceuticals quality controls

Quality control (QC) procedures should always be performed following radiopharmaceutical preparation and prior to patient administration. The main aim of QC is to ensure optimal radiopharmaceutical product properties except for some short half-life tracers such as some positron emission tomography (PET) imaging probs. by dispensing a radiopharmaceutical of the highest quality the risk of having...

متن کامل

ASHP statement on bar-code verification during inventory, preparation, and dispensing of medications.

Position The American Society of HealthSystem Pharmacists encourages hospital and health-system pharmacies to incorporate bar-code scanning into inventory management, dose preparation and packaging, and dispensing of medications. The purpose of such scanning is to ensure that drug products distributed, deployed to intermediate storage areas, or used in the preparation of patient doses are the c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2012