Interpretation of MRSASelect screening agar at 24 hours of incubation.
نویسندگان
چکیده
An incubation time of 24 h at 35 to 38 degrees C is recommended for the optimal performance of MRSASelect (Bio-Rad) chromogenic screening agar. An additional 24 h is required to capture slow-growing methicillin-resistant Staphylococcus aureus (MRSA). However, the normal hours of operation for most laboratories cannot reliably accommodate 24-h interpretation intervals. Daily agar plate interpretations are more likely to occur around 18 h and 42 h of incubation, which may compromise the performance of the chromogenic agar and negatively impact patient infection control efforts. In order to validate the importance of stringent incubation times to plate performance, we evaluated MRSASelect medium at controlled intervals of 24 and 48 h of incubation, using clinical MRSA-screening swabs. A total of 1,071 MRSA-positive and 2,733 MRSA-negative cultures were selected for analysis. Compared to 48-h-incubation results, the sensitivity and specificity of MRSASelect at 24 h were 98.3% and 98.2%, respectively. Only 19 of 1,071 (1.8%) MRSA-positive isolates required 48 h for detection. Holding 24-h negative plates an additional 24 h resulted in the workup of 253 (6.6%) pink, yet non-MRSA, colonies. The 24-h positive and negative predictive values of MRSASelect, assuming MRSA prevalences of 1, 5, and 10%, were 35.5 and 99.98%, 74.2 and 99.9%, and 85.9 and 99.8%, respectively. MRSASelect medium held for 24-h incubation is a highly sensitive and specific MRSA-screening tool. Further incubation prolongs the turnaround time for results and creates a significant amount of unnecessary work in the laboratory.
منابع مشابه
Multicenter Evaluation of MRSASelect II Chromogenic Agar for Identification of Methicillin-Resistant Staphylococcus aureus from Wound and Nasal Specimens
Hospitals strive to reduce methicillin-resistant Staphylococcus aureus (MRSA) prevalence via active surveillance of inpatient populations. Rapid and inexpensive screening methods are utilized when molecular methods are not operationally feasible. In this multisite clinical trial, the utility of Bio-Rad's MRSASelect II was evaluated for MRSA identification from remnant nares and wound swabs. The...
متن کاملEvaluation of chromogenic media for detection of methicillin-resistant Staphylococcus aureus.
Rapid laboratory diagnosis is critical for treating, managing, and preventing methicillin-resistant Staphylococcus aureus (MRSA) infections. We evaluated and compared the potential for MRSA detection of five chromogenic media, Brilliance MRSA agar (Oxoid), ChromID (bioMérieux), MRSASelect (Bio-Rad), CHROMagar (CHROMagar Microbiology), and BBL-CHROMagar (BD Diagnostics). Media were tested with l...
متن کاملAutomated Scoring of Chromogenic Media for Detection of Methicillin-Resistant Staphylococcus aureus by Use of WASPLab Image Analysis Software.
Recently, systems have been developed to create total laboratory automation for clinical microbiology. These systems allow for the automation of specimen processing, specimen incubation, and imaging of bacterial growth. In this study, we used the WASPLab to validate software that discriminates and segregates positive and negative chromogenic methicillin-resistant Staphylococcus aureus (MRSA) pl...
متن کاملReductions in workload and reporting time by use of methicillin-resistant Staphylococcus aureus screening with MRSASelect medium compared to mannitol-salt medium supplemented with oxacillin.
Methicillin-resistant Staphylococcus aureus (MRSA) is a significant pathogen in both nosocomial and community settings, and screening for carriers is an important infection control practice in many hospitals. In this retrospective study, we demonstrate that the implementation of an MRSA screening protocol using a selective chromogenic medium (MRSASelect) reduced the workload for this screening ...
متن کاملRapid isolation of salmonellae from faeces.
Factors and techniques leading to the more rapid isolation of salmonellae from faeces that are negative by direct plating were examined. The aim was to increase the number of specimens on which positive reports might be given within 24 hours of receipt. Salmonellae were isolated from 279 of the specimens studied. Brilliant green MacConkey agar was found to be the most satisfactory solid selecti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 47 3 شماره
صفحات -
تاریخ انتشار 2009