Conjunctival displacement to the corneal side for oblique-parallel insertion in 25-gauge vitrectomy.

نویسندگان

  • H Shimada
  • H Nakashizuka
  • T Hattori
  • R Mori
  • Y Mizutani
  • M Yuzawa
چکیده

PURPOSE To assess the usefulness of the method of oblique-parallel trocar insertion with conjunctival displacement to the corneal side in 25-gauge (G) transconjunctival vitrectomy. METHODS 25-G vitrectomy was performed in 77 consecutive eyes. Before making obliqueparallel trocar insertions, the conjunctiva was conventionally displaced superiorly in 35 eyes, but was displaced toward the corneal side in 42 eyes. After surgery, the distance between the scleral and conjunctival wounds was measured with calipers. The frequency of scleral wound exposure was assessed. RESULTS After cannula removal at the end of surgery, inferior repositioning of the superiorly displaced conjunctiva was observed, while marked posterior repositioning of the corneal side caused displacement of the conjunctiva due to gravity. The superior displacement distances between the sclera and conjunctival wounds were 2.4+/-0.3 mm at the infusion port, 2.0+/-0.4 mm at the superior temporal port, and 1.9+/-0.4 mm at the superior nasal port, while the corresponding distances for corneal side displacement were 3.6+/-0.5, 3.5+/-0.5, and 2.5+/-0.5mm, and were all significantly (p<0.0001) greater with corneal side displacement. The frequency of scleral wound exposure due to conjunctival damage around the cannula (infusion port) was significantly (p=0.0164) lower for corneal side displacement (0/42; 16.7%) than superior displacement (5/35; 14.3%). There was no postoperative endophthalmitis in all 77 patients studied. CONCLUSIONS In 25-G transconjunctival vitrectomy, using oblique-parallel trocar insertions with the conjunctiva displaced toward the corneal side results in marked posterior repositioning of the conjunctiva after cannula extraction. Corneal side conjunctival displacement is technically easy and completely covers the scleral wound. This method is expected to be effective in preventing endophthalmitis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative endoscopic observation of sclerotomy site after cannula removal for 23-gauge vitrectomy

BACKGROUND The purpose of this study was to determine the incidence of vitreous incarceration in sclerotomy after cannula removal during 23-gauge vitrectomy. METHODS Thirty-seven eyes underwent 23-gauge sutureless vitrectomy. Oblique sclerotomies were made parallel to the limbus and tangentially to the sclera. Once past the trocar sleeve, the angle was changed to 90 degrees perpendicular to t...

متن کامل

Successful treatment of corneal wasp sting-induced panuveitis with vitrectomy

BACKGROUND This study aims to present the management and clinical findings of a case of corneal wasp sting and to report the outcome of corneal change and panuveitis after vitrectomy. FINDINGS Clinical findings, anterior segment photographs, corneal endothelial changes, and medical treatment of corneal wasp sting-induced panuveitis are presented. A 95-year-man was stung by a wasp on his left ...

متن کامل

Investigation of postoperative intraocular pressure in cases of silicone oil removal using 25-gauge transconjunctival sutureless vitrectomy with oblique incisions

BACKGROUND The purpose of this study was to investigate postoperative intraocular pressure (IOP) in cases of silicone oil (SO) removal when using 25-gauge transconjunctival sutureless vitrectomy (TSV) with oblique incisions. METHODS We enrolled ten consecutive eyes with SO removal (SO group) and eleven consecutive eyes with idiopathic epiretinal membrane (ERM) as the initial vitrectomy (ERM g...

متن کامل

A comparison study of corneal topographic changes following 20-, 23-, and 25-G pars plana vitrectomy.

PURPOSE To evaluate and compare corneal topographic changes following pars plana vitrectomy with the 23-gauge (G) and 25-G transconjuntival sutureless vitrectomy system as well as the standard 20-G vitrectomy system. METHODS We prospectively evaluated corneal topographic changes in 45 eyes of 45 patients divided into three groups according to vitrectomy system used (20-, 23-, and 25-G). All p...

متن کامل

Transcorneal three-port vitrectomy without conjunctival incision.

Aim: To evaluate the safety and outcomes of trans corneal three port vitrectomy without conjunctival incision. Methods: A total of 27 patients were included in the study. out of which 13 patients were with posteriorly dislocated PCIOL (posterior chamber intra ocular lens), 9 patients with dropped cortical lens matter and 5 patients with vitreous hemorrhage. In all these patients, we made three ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of ophthalmology

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2008