Determination of Available Transfer Capability (ATC) Considering Integral Square Generator Angle (ISGA)

نویسندگان

  • M. M. OTHMAN
  • I. MUSIRIN
  • A. MOHAMED
  • A. HUSSAIN
  • Shah Alam
چکیده

This paper presents the determination of power transfer between two buses that takes into account the dynamic security constraint. The dynamic security constraint based transient stability has been found to be one of the limiting factors in determining the power transfer so-called as the available transfer capability (ATC). The multimachine integral square generator angle (ISGA) index is used to measure the severity of stable and unstable transient events during the occurrence of line outage that is considered in the ATC assessment. The determination of ATC considering dynamic security constraint has been performed on a case study of 6 bus system. Key-Words: Integral square generator angle, available transfer capability and line outage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Evaluation of Available Transfer Capability (ATC) Considering Integral Square Generator Angle (ISGA)

One of the concepts in restructuring the electric power industry is the ability to accurately and rapidly quantify the power transfer so-called as the available transfer capability (ATC). Accurate identification of ATC provides vital information for both planning and operation of the bulk power market in reserving transmission services. There are various methods used to determine ATC such as th...

متن کامل

A New Algorithm for the Available Transfer Capability Determination

This paper presents a fast and accurate method to determine the available transfer capability. Ralston’smethod is used to predict the two trajectory points of voltagemagnitude, power flow, and maximum generator rotor angle difference. Then, the cubic spline interpolation technique is used to accurately trace the P-V, P-S, or P-Δδ curves between two points of trajectory. The P-V, P-S and PΔδ cur...

متن کامل

Assessment of ATC Using Voltage and Transient Stability, Simultaneously

Methods for calculating Available Transfer Capability (ATC) of the transmission systems may be grouped under Static and Dynamic methods. This paper presents a fast dynamic method for ATC calculations, which considers both Transient Stability Limits and Voltage Stability Limits as terminating criteria. A variation of Energy Function Method is used to determine the transient stability limit and t...

متن کامل

Assessment of ATC Using Voltage and Transient Stability, Simultaneously

Methods for calculating Available Transfer Capability (ATC) of the transmission systems may be grouped under Static and Dynamic methods. This paper presents a fast dynamic method for ATC calculations, which considers both Transient Stability Limits and Voltage Stability Limits as terminating criteria. A variation of Energy Function Method is used to determine the transient stability limit and t...

متن کامل

A Multi-Year Scenario-Based Transmission Expansion Planning Model Incorporating Available Transfer Capability

This paper presents a multi-year scenario-based methodology for transmission expansion planning (TEP) in order to enhance the available transfer capability (ATC). The ATC is an important factor for all players of electricity market who participate in power transaction activities and can support the competition and nondiscriminatory access to transmission lines among all market participants. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007