Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity modulated therapy
نویسندگان
چکیده
PURPOSE A study was performed comparing dosimetric characteristics of volumetric modulated arcs (RapidArc, RA) and fixed field intensity modulated therapy (IMRT) on patients with bilateral breast carcinoma. MATERIALS AND METHODS Plans for IMRT and RA, were optimised for 10 patients prescribing 50 Gy to the breast (PTVII, 2.0 Gy/fraction) and 60 Gy to the tumour bed (PTVI, 2.4 Gy/fraction). Objectives were: for PTVs V(90%)>95%, D(max)<107%; Mean lung dose MLD<15 Gy, V(20Gy)<22%; heart involvement was to be minimised. The MU and delivery time measured treatment efficiency. Pre-treatment dosimetry was performed using EPID and a 2D-array based methods. RESULTS For PTVII minus PTVI, V(90%) was 97.8 +/- 3.4% for RA and 94.0 +/- 3.5% for IMRT (findings are reported as mean +/- 1 standard deviation); D(5%)-D(95%) (homogeneity) was 7.3 +/- 1.4 Gy (RA) and 11.0 +/- 1.1 Gy (IMRT). Conformity index (V(95%)/V(PTVII)) was 1.10 +/- 0.06 (RA) and 1.14 +/- 0.09 (IMRT). MLD was <9.5 Gy for all cases on each lung, V(20Gy) was 9.7 +/- 1.3% (RA) and 12.8 +/- 2.5% (IMRT) on left lung, similar for right lung. Mean dose to heart was 6.0 +/- 2.7 Gy (RA) and 7.4 +/- 2.5 Gy (IMRT). MU resulted in 796 +/- 121 (RA) and 1398 +/- 301 (IMRT); the average measured treatment time was 3.0 +/- 0.1 minutes (RA) and 11.5 +/- 2.0 (IMRT). From pre-treatment dosimetry, % of field area with gamma <1 resulted 98.8 +/- 1.3% and 99.1 +/- 1.5% for RA and IMRT respectively with EPID and 99.1 +/- 1.8% and 99.5 +/- 1.3% with 2D-array (DeltaD = 3% and DTA = 3 mm). CONCLUSION RapidArc showed dosimetric improvements with respect to IMRT, delivery parameters confirmed its logistical advantages, pre-treatment dosimetry proved its reliability.
منابع مشابه
Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملComparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison
Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...
متن کاملVolumetric modulated arc therapy with simultaneous integrated boost for locally advanced rectal cancer.
AIMS To report the feasibility of volumetric modulated arc therapy (VMAT) for neoadjuvant radiotherapy in locally advanced rectal cancer in a dose-escalation protocol and simultaneous integrated boost (SIB) approach. Moreover, the VMAT technique was compared with three-dimensional conformal radiotherapy (3D-CRT) and fixed-field intensity modulated radiotherapy (IMRT), in terms of target coverag...
متن کاملIntensity modulated radiotherapy with fixed collimator jaws for locoregional left-sided breast cancer irradiation
The purpose of this study is to evaluate the intensity modulated radiotherapy (IMRT) with the fixed collimator jaws technique (FJT) for the left breast and regional lymph node. The targeted breast tissue and the lymph nodes, and the normal tissues were contoured for 16 left-sided breast cancer patients previously treated with radiotherapy after lumpectomy. For each patient, treatment plans usin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation Oncology (London, England)
دوره 4 شماره
صفحات -
تاریخ انتشار 2009