Development of FIA equipped with a chemiluminescence detector using a mixed reagent of luminol and 1,10-phenanthroline.

نویسندگان

  • Kazuhiko Tsukagoshi
  • Masayuki Tahira
  • Riichiro Nakajima
چکیده

We developed an FIA system equipped with a chemiluminescence detector using a mixed chemiluminescence reagent of luminol and 1,10-phenanthroline for the detection of metal ions and metal complexes. The carrier, mixed chemiluminescence reagent comprising luminol, 1,10-phenanthroline, and cethyltrimethylammonium bromide, and H2O2 solutions were fed by corresponding pumps at a definite flow rate. Sample solutions dissolving hematin, [Co(NH3)4(H2O)2]2(SO4)3, CuSO4, NiCl2, K3[Fe(CN)6], and K4[Fe(CN)6] were analyzed as models by the means of the present FIA system. Solutions of hematin, [Co(NH3)4(H2O)2]2(SO4)3, CuSO4, and NiCl2 were detected as positive peaks, as usual. The order of the catalytic activity of these samples for the present chemiluminescence reaction using the mixed chemiluminescence reagent was [Co(NH3)4(H2O)2]2(SO4)3 > hematin > CuSO4 > NiCl2. On the other hand, sample solutions of K3[Fe(CN)6] and K4[Fe(CN)6] were detected as negative peaks and were determined over the ranges of 1 x 10(-8) - 1 x 10(-6) M with a detection limit of 1 x 10(-8) M and 2 x 10(-8) - 4 x 10(-6) M with a detection limit of 2 x 10(-8) M, respectively. Their negative peaks were observed reproducibly with a relative standard deviation of 2 - 5%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A four-wavelength channel absorbance detector with a light emitting diode-fiber optics assembly for simplifying the flow-injection analysis system.

A four-channel absorbance detector was developed for simplifying the flow-injection analysis (FIA). This detector used four light-emitting-diodes (LEDs) as light sources; their wavelengths were 470, 495, 590 and 635 nm, respectively. Their amplitudes were modulated electronically with different frequencies. The light emissions from them were merged by plastic-core fiber optics, and were detecte...

متن کامل

Determination of Total Antioxidant Activity of Wines Using a Flow Injection Method with Chemiluminescence Detection

Total antioxidant capacity (TAC) of several samples of red and white wines was investigated by means of a new analysis method of flow injection with chemiluminescence detection ((FIA-CL). The applied method is based on a chemiluminescence reaction between luminol and hydroxyl radicals generated by the hydrogen peroxide in the presence of Co(II) ions complexed with ethylene diamine tetraacetic a...

متن کامل

Simultaneous analysis of plural samples in a CE-CL detector possessing micro-space area for reaction/detection.

Plural samples were simultaneously analyzed in a capillary electrophoresis (CE)-chemiluminescence (CL) detector system, taking advantage of a micro-space area for reaction/detection at the tip of the capillary. The CL reaction of 1,10-phenanthroline and hydrogen peroxide was adopted and a Cu(II) sample was used as a model. Three different length capillaries were inserted into a flow-type CL det...

متن کامل

Study of the effects of CO2(g) on the Fe(II)-luminol chemiluminescence system: application to ultra-trace analysis of Fe(II)

The Fe(II)-catalyzed oxidation of luminol has been a well-accepted chemiluminescence method for the trace and ultra-trace analysis of Fe(II) and Fe(III) in natural waters. Investigation into this chemiluminescence system has shown that COlg) is essential to Fe-catalyzed luminol chemiluminescence. In absence of CO2(g) there is no chemiluminescent signal. These reactions worked well in the past b...

متن کامل

Chemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System

A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 7  شماره 

صفحات  -

تاریخ انتشار 2003