The correction for the gamma-ray component in neutron therapy.
نویسندگان
چکیده
Neutron beams for therapy always contain some gamma ray contamination that varies with depth and with distance from the beam axis. The problem therefore arises how the varying gamma ray contribution should be accounted for in dose specification. Not infrequently a "total effective dose" DE is quoted that is equal to the neutron dose plus the gamma ray dose divided by a constant weight factor tau. On general biophysical considerations this appears to be not a valid approach since it must be assumed that tau decreases with increasing dose. The nature and the magnitude of this dose dependence is derived in the present article. Application of the results to actual doses per fraction and to factual gamma ray to neutron ratios demonstrates that the dose dependence of tau has, in fact, very minor influence on the numerical values of DE. Utilization of a constant value tau is therefore satisfactory in practice.
منابع مشابه
Investigation of neutron flux by thermoluminescence dosimeters in the neutron-gamma mixed field
Introduction: Neutrons have many applications in various fields, such as medicine. The important application of neutron in medical science is in Boron Neutron Capture Therapy (BNCT). Because of this, determination of neutron dose and flux is critical for the health maintaining of workers and patients exposed to this beam. The neutron radioisotope sources produce gamma rays in ...
متن کاملShielding studies on a total-body neutron activation facility
Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...
متن کاملTitle Design of light element analysis system in BNCT and every NCT
Introduction: The Monte Carlo simulation is used to enhance reliability in the experiments related to nuclear instruments. in addition, that is used to calculate the different components of the neutron and gamma ray fluxes in boron neutron capture therapy(BNCT) and neutron capture (NCT)applications. BNCT is one of the methods in radiotherapy, that is used the neutron beam for ki...
متن کاملA Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom
Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...
متن کاملMonte Carlo characterization of photoneutrons in the radiation therapy with high energy photons: a Comparison between simplified and full Monte Carlo models
Background: The characteristics of secondary neutrons in a high energy radiation therapy room were studied using the MCNPX Monte Carlo (MC) code. Materials and Methods: Two MC models including a model with full description of head components and a simplified model used in previous studies were implemented for MC simulations. Results: Results showed 4-53% difference between full and wit...
متن کاملCalculation and evaluation of the vital head organs dose during Neutron Therapy in Tehran Research Reactor using Zubal phantom
In the recent years some studies has been done to consider the capability of Tehran Research Reactor for Boron neutron capture therapy (BNCT). The purpose of this study is to evaluate the sensitive organs dose during the treatment of patient with deep brain tumor by TRR. The calculation has been carried out using the Monte Carlo code MCNPX for ZUBAL head and neck phantom. The method was tested ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 7 5 شماره
صفحات -
تاریخ انتشار 1980