Choosing and using the AcrySof IQ ReSTOR IOL family
نویسندگان
چکیده
منابع مشابه
Does the apodized diffractive intraocular lens Acrysof ReSTOR Natural interfere with FDT Matrix perimetry results?
PURPOSE To compare the effect of an apodized diffractive intraocular lens (IOL) (Acrysof ReSTOR Natural) and its yellow counterpart (Natural IQ) on frequency doubling technology (FDT) perimetry results. METHODS This study included 37 eyes from 22 patients at the 'Centro Oftalmológico Tranjan' who had undergone uncomplicated phacoemulsification and intraocular lens implantation (17 Acrysof ReS...
متن کاملMinus Piggyback Lens Overlaying ReSTOR® Multifocal Lens in High Myopia
BACKGROUND We report the case of a 40-year-old female patient treated with implantation of the Acrysof® IQ ReSTOR® lens (Alcon, Fort Worth, Tex., USA) with overlaying Acrysof EXpand® minus piggyback lens (Alcon). METHODS The patient had high myopia and was diagnosed with presbyopia and bilateral posterior subcapsular cataract. She desired to be spectacle-free and opted to undergo bilateral pl...
متن کاملVisual performance of Acrysof ReSTOR compared with a monofocal intraocular lens following implantation in cataract surgery
The aim of this study was to compare the visual performance of Acrysof ReSTOR and Acrysof Natural intraocular lenses (IOLs) following cataract surgery. A randomized prospective study was performed in which 64 eyes (51 patients) were divided randomly into two groups. Monofocal IOLs (Acrysof Natural) were implanted into 34 eyes (27 patients) and multifocal IOLs (Acrysof ReSTOR) were implanted int...
متن کاملOptical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens
PURPOSE The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. METHODS The optical characteristics of AcrySof(®) IQ PanOptix™ (PanOptix) and AcrySof(®) IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal i...
متن کاملDisk halo size measured in individuals implanted with monofocal versus diffractive multifocal intraocular lenses
METHOD: Halo radius was measured using a vision monitor (MonCv3) with low-luminance optotypes in 39 eyes that had cataract surgery and the bilateral implant of an Acrysof Restor SN6AD1 multifocal IOL or Acrysof IQ monofocal IOL 6 to 9 months previously. The visual angle subtended by the disk halo radius was calculated in minutes of arc (arcmin). Patient complaints of halo disturbances were reco...
متن کامل