SPECT imaging with off-set detector system: comparison of sampling angles 2, 4 and 6 degrees.
نویسندگان
چکیده
PURPOSE We evaluated an off set reconstruction method for single photon emission computed tomography (SPECT), and compared it with the conventional on set reconstruction method, using sampling angles of 2, 4, and 6 degrees. METHOD A triple-detector system was used. In the off-set acquisition, sampling angles of the opposite detector were shifted 1/2 of the sampling angles of 2, 4, and 6 degrees. For example, when projection data were acquired every 6-degrees (sampling angle = 6 degrees), the projection angles were at 0 degrees, 6 degrees, 12 degrees, and 174 degrees with one detector, and 177 degrees, 183 degrees, 189 degrees, and 357 degrees with the other, opposite, detector. The conventional on set reconstruction images were compared with an off set reconstruction for a pool phantom of uniform concentration, a hot rods phantom, a myocardial phantom, and a human study. RESULTS The off set reconstruction method was better at all three sampling angles. FWHM (mm) were 11.02 at off-set versus 11.17 at on-set (sampling angle 2 degrees), 11.13 at off-set versus 11.48 at on-set (sampling angle 4 degrees), and 11.24 at off-set versus 11.64 at on-set (sampling angle 6 degrees), respectively. In human myocardium SPECT, visualization of the interventricular septum and cardiac cavity was improved. CONCLUSION Off set reconstruction by means of filtered back projection will be an efficient sampling mode, having a larger number of effective projection angles.
منابع مشابه
The effect of earth magnetic field on the function of nuclear medicine imaging systems (SPECT)
Background: The nuclear medicine systems are very sensitive to the variation of the magnetic field. Photomultiplier tubes amplify low energy light signal and change it into electrical current. Low magnetic field can produce some variations in uniformity and special resolution of SPECT systems. In this study, we tried to evaluate the effects of magnetic field on the function of nuclear medic...
متن کاملOptimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...
متن کاملDual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector.
Objective(s): The energy resolution of a cadmium-zinc-telluride (CZT) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional Anger type detector which is 10%. Also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. In this study, we used a semiconductor detector and examined the ef...
متن کاملDevelopment of a collimator blurring compensation method using fine angular sampling projection data in SPECT.
Due to the collimator aperture, spatial resolution of SPECT data varies with source-to-detector distance. Since the radius of detector rotation is bigger when scanning larger patients, spatial resolution is degraded in these cases. Emitted gamma rays travel not only along the central axis of the collimator hole but also off-axis due to the collimator aperture. However, an off-axis ray at one an...
متن کاملOptimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method
Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2002