The Value of Serum Immunoglobulin Free Light Chain Assessment in Patients with Monoclonal Gammopathies and Acute Renal Failure

نویسندگان

  • Mustafa Cirit
  • Atilla Üzüm
  • Pınar Özen
  • Banu A. Şentürk
  • Giray Bozkaya
  • Bahriye Payzin
  • Orçun Ural
چکیده

OBJECTIVE Immunoglobulin free light chain (FLC) abnormalities are common in patients with monoclonal gammopathies and the kidneys are the most affected organs. Immunoassays that provide quantitative measurement of FLC in serum indicate monoclonal FLC production based on the presence of an abnormal FLC kappa:lambda (κ:λ) ratio. The aim of this study was to assess the utility of serum FLC measurement as a diagnostic tool for detecting plasma cell dyscrasias in comparison to standard assays, and to ascertain its sensitivity and specificity in patients with acute renal failure (ARF). MATERIAL AND METHODS Sera from 82 patients with ARF were assessed using serum protein electrophoresis (SPE), serum immunofixation electrophoresis (SIFE), and FLC measurement. The sensitivity and specificity of the FLC ratio in identifying which ARF patients had multiple myeloma (MM) was compared to those of SPE and SIFE. RESULTS Among the 82 patients with ARF, 7 were diagnosed as MM using SPE, SIFE, and bone marrow biopsy techniques. In total, 8 patients did not have a FLC κ:λ ratio that was within the published reference range (0:26-1:65); the FLC κ:λ ratio based on FLC measurement had a specificity of 96% and sensitivity of 71%, and positive and negative predictive values of 62.9% and 97.3%, respectively, for the diagnosis of MM. CONCLUSION The sensitivity and specificity of the FLC κ:λ ratio for diagnosing MM in patients that presented with ARF were lower than those of SPE and SIFE. To further delineate the utility of the FLC κ:λ ratio additional prospective, well-designed large-scale studies are needed. CONFLICT OF INTEREST None declared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum Free Light-chain Assay for the Diagnosis, Management, and Prognosis of Multiple Myeloma

In recent decades, new serum biomarkers have been developed for routine laboratory practice, such as assaying serum free light chains and more recently, assaying immunoglobulin heavy and light chain isotypes (Hevylite). In this work, we highlight the interest of new biomarkers (Hevylite Test) in the management of monoclonal gammopathies because of the technical advantages it confers and the se...

متن کامل

Serum free light chains: an alternative to the urine Bence Jones proteins screening test for monoclonal gammopathies.

BACKGROUND Retrospective analyses have established the role of quantitative serum free light chains (FLCs) in the diagnosis of monoclonal light chain disorders. The aims of this study were to assess (a) whether the addition of serum FLCs to serum protein electrophoresis (SPEP) identified additional patients with monoclonal gammopathies; (b) whether serum FLC measurements could replace urinalysi...

متن کامل

Serum free light chain assays not total light chain assays are the standard of care to assess Monoclonal Gammopathies.

The diagnosis of Multiple Myeloma is a challenge to the physician due to the non-specific symptoms (anemia, bone pain and recurrent infections) that are commonplace in the elderly population. However, early diagnosis is associated with less severe disease, including fewer patients presenting with acute renal injury, pathological fractures and severe anemia. Since 2006, the serum free light chai...

متن کامل

Serum Free Light Chains: An Alternative Test to Urine Bence Jones Proteins When Screening for Monoclonal Gammopathies

Background: Retrospective analyses have established the role of quantitative serum free light chains (FLCs) in the diagnosis of monoclonal light chain disorders. The aims of this study were to assess (a) whether the addition of serum FLCs to serum protein electrophoresis (SPEP) identified additional patients with monoclonal gammopathies; (b) whether serum FLC measurements could replace urinalys...

متن کامل

The anion gap and routine serum protein measurements in monoclonal gammopathies.

BACKGROUND AND OBJECTIVES An abnormal anion gap and an increased total protein and globulin are clues to the diagnosis of monoclonal gammopathy. We explored the utility of these markers in IgG, IgA, IgM, and free light chain monoclonal gammopathies. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS The anion gap, Na(+) - (Cl(-) + HCO(3)(-)), corrected for hypoalbuminemia, was calculated in patien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2012