A Method for Obtaining the Electric Arc Model Parameters for SF6 Power Circuit Breakers

نویسنده

  • S. MAXIMOV
چکیده

Abstract: In this work, a new method for calculating the parameters of electric arc model for SF6 power circuit breaker is proposed. The methodology consists in the optimization of a theoretical function with respect to a group of model parameters in order to achieve a better approximation to a set of experimental data. The theoretical function is an asymptotic solution of the equation for the electric arc model obtained in a selected period of time. The developed method is applied to calculate the parameters of an arc model previously published in the literature. By using the variation of the cooling power, an improved electric arc model is also obtained including its parameters. The new model has a very compact form and exhibit a good correlation between voltage curves measured and calculated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating Characteristics of N2, CO2 and CF3I in Contrast to High Current Arcs in Circuit Breakers to Choose a Suitable Substitute for SF6

Specific and sensitive operation of circuit breakers makes an individual position for them in power networks. Circuit breakers are at the central gravity of variations and execution operations. Therefore, an optimum operation is the main reason to investigate about new gases to be used in MV and HV circuit breakers instead of SF6. The arc process has enormous complexity because of hydrodynamic ...

متن کامل

Reliability Based Optimal Preventive Maintenance Policy for High Voltage Circuit Breakers in Power Plants

  Electric power industry have always try to provide reliable electricity to customers and at the same time decrease system costs. High Voltage circuit-breakers are an essential part of the power network. This study has developed a maintenance and replacement scheduling model for high voltage circuit- breakers that minimize maintenance costs while maintaining the acceptable reliability. This mo...

متن کامل

Analysis of Electric Field and Polarization of SF6 Circuit Breaker to Approach a Suitable Structure

Abstract: The application of electric field theory to widely different aspects of electrical insulation has led to more understanding the phenomena. Electric fields may be considered as the main reason for insulation failure. The purpose of this paper is to modify importance of analyzing electric field in insulation design. The SF6 circuit breaker is chosen as case study that encounters cri...

متن کامل

Synoptic Approach of Synchronous Generator on Disconnection Processes in Electric Power Systems Comprising Generator Circuit Breakers

This paper is a sequel to a study by the authors of electric power systems comprising the generator circuit-breakers (GCBs) at power plant generator terminals. A sustainable assessment of the current interruption requirements of a GCB addresses the main stresses on the generator circuit breaker, revealing that the GCB current interruption requirements are significantly higher than for the distr...

متن کامل

A Probabilistic Three-Phase Time Domain Electric Arc Furnace Model based on analytical method

An electric arc furnace (EAF) is known as nonlinear and time variant load that causes power quality (PQ) problems such as, current, voltage and current harmonics, voltage flicker, frequency changes in power system. One of the most important problems to study the EAF behavior is the choice of a suitable model for this load. Hence, in this paper, a probabilistic three-phase model is proposed base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009