Numerical investigation of absorption dose distribution of onion powder in electron irradiation system by MCNPX code

نویسنده

  • T. Taherkhani
چکیده

a Department of physics, faculty of science, Takestan Branch, Islamic Azad University,Takestan, IRAN. b Engineering Department, Shahid Beheshti University, G.C., P.O. Box 1983963113, Tehran, IRAN. ________________________________________________________________________________________ Abstract: Absorption dose distribution of onion powder in electron irradiation system has been numerically investigated by using of MCNPX (Monte Carlo N-Particle extended) software package and the real parameters of the Rhodotron Accelerator at Yazd Radiation Processing Center (YRPC) of Atomic Energy Organization of Iran (AEOI). The simulations were carried out for the cases in which the onion powder was irradiated by one sided and double-sided electron irradiation and with homogeneous and inhomogeneous sample structures. The line dose profiles and surface dose profile, as well as iso-dose profiles for different depths, and 3D profile of dose distributions in each case were also studied. The simulation results indicated that the dose distribution for double-sided irradiation is uniform and its maximum is in the center. The results also showed that the maximum of depth–dose curve on one-side and double-side irradiation is up to maximal value of 33 kGy and 44 kGy, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of environmental dose distribution of nuclear gauge device MC-1DR by MCNPX code

In this study, distribution of dose rate around the nuclear gauge device MC-1DR which located in shahrekord university was simulated by MCNPX code and was compared whit the measured values. Due to the asymmetry of device and neutron and gamma source positions, the dose rates were determined at a distance of 5, 30 and 100 cm in different directions. Base on the complex geometry of the inside of ...

متن کامل

Designing CT scanning rooms and estimating patient and personnel absorbed dose using code (MCNPX 2.6)

One of the most widely used diagnostic devices in medical imaging is computed tomography scanning with the use of X-ray ionization. After years of using this tool in the diagnosis and treatment, external doses of these beams can pose a risk of secondary cancer, which is significant in terms of radiation safety and protection. In this paper, using the Monte Carlo code MCNPX2.6 performed over thr...

متن کامل

Making a novel method to obtain the required irradiation time in fast neutron radiation therapy of liver tissue

During radiotherapy by any radiation, it is always essential to stop absorbing the excess dose by a tissue. To better treat cancerous tissues and to make more precise irradiation for a cancerous tumor, there needs the accurate irradiation time to be estimated. First, the constituent materials of any of the existing organs in abdominal tissue are extracted and defined in the MCNPX code. Then, ev...

متن کامل

Comparison and Evaluation of the Effects of Rib and Lung Inhomogeneities on Lung Dose in Breast Brachytherapy using a Treatment Planning System and the MCNPX Code

Introduction: This study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (TPS) for 192Ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. Materials and Methods: A CT scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...

متن کامل

Calculation the accumulated dose in the heart and its effect on other human organs by using experimental mouse data and the MCNPX code for FDG

Introduction: The use of ionizing radiation in diagnostic medicine is expanding, and considering the fact that the practical dosimeter in a precise way is almost impossible, the Monte Carlo computational methods help researchers, to have coming up the lowest cost and error of the distribution of doses in the patient's body.   Materials and Methods: In this st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014