Management of Intra-Aortic Balloon Pump Rupture and Entrapment.

نویسندگان

  • Madhu Bhamidipaty
  • Barend Mees
  • Timothy Wagner
چکیده

While the intra-aortic balloon pump (IABP) itself has many useful and life-saving indications, it has a high complication rate, up to 30% in some studies. This report discusses the surgical removal and subsequent vascular repair in a patient with a ruptured and subsequently entrapped IABP and reviews the literature on the presentation and management of this rare but major complication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra-Aortic Balloon Pump Rupture and Entrapment

Intra-aortic balloon pump is used frequently to support a failing myocardium in cardiac patients. Due to the invasive nature of this device, usage is accompanied by consistent risk of complications. Balloon rupture, although it occurs rarely, may lead to entrapment if diagnosis delays. A 78-year male who underwent cardiac surgery experienced balloon rupture and entrapment in the right femoral a...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

[Left ventricular rupture of mitral valve prosthesis implantation treated using an intra-aortic balloon pump counterpulsation].

Left ventricular rupture is an infrequent but potentially fatal complication of mitral valve replacement. In spite of the fact that several methods of repair have previously been described, the mortality rate remains nearly 85%. The use of the intra-aortic balloon pump counterpulsation may increase the possibilities of success in the repair of this dreaded complication. We present here three ca...

متن کامل

Intra-Aortic Balloon Pump Entrapment in a Nonatherosclerotic Common Iliac Artery.

Use of an intra-aortic balloon pump (IABP) is helpful for maintaining hemodynamic stability in patients with low cardiac output and compromised left ventricular function undergoing coronary artery bypass grafting. Although the incidence of complications has decreased significantly as experience with the device has increased, IABP use still carries a risk of complications. The most common compli...

متن کامل

Portal venous gas entrapment secondary to mesenteric ischemia after withdrawal of intra-aortic balloon pump: A case report with a rare ultrasound image

After coronary artery bypass graft (CABG), mesenteric ischemia is a rare but dreadful complication with high mortality rates. Prophylactic use of intra-aortic balloon pump (IABP) is a common practice in patients with severe coronary artery disease awaiting CABG. During withdrawal of the IABP, there is a risk of dislodging atheromatous debris, thus causing peripheral and mesenteric emboli, which...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aorta

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2016