Stability of the EasyOne ultrasonic spirometer for use in general practice.

نویسندگان

  • Julia A E Walters
  • Richard Wood-Baker
  • Justin Walls
  • David P Johns
چکیده

OBJECTIVE AND BACKGROUND Spirometry is recommended for the diagnosis and management of chronic respiratory diseases in the community. Spirometer accuracy is critical, but few general practitioners meet the American Thoracic Society and European Respiratory Society (ATS/ERS) recommendation for daily calibration. The aim of this study was to assess the accuracy and stability of a portable ultrasonic spirometer (EasyOne) that the manufacturer claims does not require regular calibration. METHODS Six EasyOne spirometers were used in a practice-based spirometry study. Inspiratory and expiratory accuracy was checked periodically using a certified 3-L syringe. Paired calibration checks were performed using a dedicated mouthpiece assembly (spirette) and randomly selected spirettes. RESULTS The six spirometers were used for up to 26 weeks (mean 23.9 weeks) and a total of 1041 spirometry tests and 75 syringe calibrations were performed. All inspiratory and expiratory calibration checks using a dedicated or randomly selected spirette met the ATS/ERS accuracy criterion (3.00+/-0.105 L). The mean (range) expiratory volume deviation from target volume (3.00 L) was 0.011 L (-0.06-0.09 L) using a dedicated spirette and 0.046 L (-0.09-0.10 L) using randomly selected spirettes. The deviation from target was not affected by the mean flow generated during the calibration procedure. There was no change in calibration during the study. CONCLUSIONS This study supports the manufacturer's claim that the EasyOne spirometer maintains its calibration during routine clinical use in general practice and does not require daily calibration as specified in international spirometry guidelines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Four-year calibration stability of the EasyOne portable spirometer.

BACKGROUND Clinical practice guidelines recommend daily spirometer calibration checks and weekly linearity checks. The long-term stability of the volume and flow accuracy of a specific model of spirometer should be carefully characterized before modification of the frequency of calibration checks is considered for that model of spirometer. METHODS The EasyOne ultrasonic flow-sensing spiromete...

متن کامل

Reproducibility and validity of a handheld spirometer.

BACKGROUND Handheld spirometers have several advantages over desktop spirometers, but worries persist regarding reproducibility and validity of data from handheld spirometers. We undertook an independent examination of the EasyOne handheld spirometer. METHODS The laboratory testing included reproducibility and validity testing with a waveform generator. We used standard American Thoracic Soci...

متن کامل

An unusual cause of patchy ground-glass opacity.

exposure matrix and its application in the epidemiological study of genetics and environment in asthma (EGEA). Occup Environ Med 2000;57:635–41. 26. American Thoracic Society. Standardization of spirometry—1987 update. Statement of the American Thoracic Society. Am Rev Respir Dis 1987;136:1285–98. 27. American Thoracic Society. Standardization of spirometry, 1994 update. Am J Respir Crit Care M...

متن کامل

The long-term stability of portable spirometers used in a multinational study of the prevalence of chronic obstructive pulmonary disease.

BACKGROUND We report the performance of an ultrasound-based portable spirometer (EasyOne) used in a population-based survey of the prevalence of chronic obstructive pulmonary disease, conducted in 5 Latin American cities: São Paulo, Brazil; México City, México; Montevideo, Uruguay; Santiago, Chile; and Caracas, Venezuela (the Latin American COPD Prevalence Study [PLATINO]). METHODS During the...

متن کامل

Quality of spirometry in primary care for case finding of airway obstruction in smokers.

BACKGROUND Diagnosis of chronic obstructive pulmonary disease (COPD) and its severity determination is based on spirometry. The quality of spirometry is crucial. OBJECTIVES Our aim was to assess the quality of spirometry performed using a spirometer with automated feedback and quality control in a general practice setting in Switzerland and to determine the prevalence of airflow limitation in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respirology

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 2006