BACKGROUND The CorneaL GrAft Thickness Evaluation (COLGATE) system was recently developed to facilitate the evaluation of corneal graft thickness from OCT images. Graft thickness measurement can be a surrogate indicator for detecting graft failure or success. The purpose of this study was to determine the reproducibility of the COLGATE system in measuring DSAEK graft area between two observers. METHODS This was a prospective case series in which 50 anterior segment OCT images of patients who had undergone DSAEK in either eye were analysed. Two observers (MW, AC) independently obtained the image analysis for the graft area using both semi automated and automated method. One week later, each observer repeated the analysis for the same set of images. Bland-Altman analysis was performed to analyze inter and intra observer agreement. RESULTS There was strong intraobserver correlation between the 2 semi automated readings obtained by both observers. (r = 0.936 and r = 0.962). Intraobserver ICC for observer 1 was 0.936 (95% CI 0.890 to 0.963) and 0.967 (95% CI 0.942 to 0.981) for observer 2. Likewise, there was also strong interobserver correlation (r = 0.913 and r = 0.969). The interobserver ICC for the first measurements was 0.911 (95% CI 0.849 to 0.949) and 0.968 (95% CI 0.945 to 0.982) for the second. There was statistical difference between the automatic and the semi automated readings for both observers (p = 0.006, p = 0.003). The automatic readings gave consistently higher values than the semi automated readings especially in thin grafts. CONCLUSION The analysis from the COLGATE programme can be reproducible between different observers. Care must be taken when interpreting the automated analysis as they tend to over estimate measurements.
منابع مشابه
Title: Reproducibility of Corneal Graft Thickness Measurements with Colgate in Patients Who Have Undergone Dsaek (descemet Stripping Automated Endothelial Keratoplasty)
متن کامل
Interface wavelike deposits after descemet stripping automated endothelial keratoplasty.
Descemet stripping automated endothelial keratoplasty (DSAEK) is a new treatment option for corneal endothelial dysfunction. Compared with penetrating keratoplasty, DSAEK is less invasive and leads to more rapid visual recovery. The most common complications after DSAEK described in the literature are graft detachment and/or dislocation, rejection, epithelial ingrowth, and pupillary block, all ...
متن کاملDescemet stripping automated endothelial keratoplasty in Fuchs’ corneal endothelial dystrophy: anterior segment optical coherence tomography and in vivo confocal microscopy analysis
BACKGROUND To evaluate the in vivo corneal changes using in vivo confocal microscopy (IVCM) and anterior segment optical coherence tomography (AS-OCT) in patients with Fuchs' dystrophy who underwent Descemet stripping automated endothelial keratoplasty (DSAEK) and the relationship between these changes and the postoperative visual recovery up to 1-year follow-up. METHODS Before DSAEK and 1 da...
متن کاملFellow eye comparison of corneal thickness and curvature in descemet membrane endothelial keratoplasty and descemet stripping automated endothelial keratoplasty.
PURPOSE To compare posterior corneal curvature in the fellow eye of the same patients after Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK). METHODS This retrospective, case series comparative study included consecutive patients who underwent DSAEK in one eye and DMEK in the fellow eye. Each eye underwent corneal evaluation w...
متن کاملDescemet stripping automated endothelial keratoplasty using cultured corneal endothelial cells in a rabbit model.
OBJECTIVE To investigate the feasibility of Descemet stripping automated endothelial keratoplasty (DSAEK) using cultured human corneal endothelial cells (HCECs) in an animal model. METHODS Descemet stripping automated endothelial keratoplasty grafts were produced by seeding cultured HCEC suspensions onto human corneal stromal discs. Three insertion techniques were assessed in an ex vivo model...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2012