Headspace oxygen in sample vial for the purge-and-trap dynamic headspace/gas chromatography method oxidizes meat if held hours before purging, influences volatile profiles, and misrepresents the true composition of volatiles. Helium flush and helium flush plus oxygen absorber were used to eliminate residual oxygen and minimize oxidative changes in meat during sample holding time. Both helium flush and helium flush plus oxygen absorber treatments were effective in preventing an increase in 2-thiobarbituric acid reactive substances (TBARSs) and volatiles production in raw meat for up to 640 min of sample holding. With helium flush plus oxygen absorber, only 1-octen-3-ol increased during the 1280-min sample holding time. However, the hexanal peak in raw meat was interfered by 2,6-dimethyl heptane when oxygen absorber was added. Therefore, use of oxygen absorber was not appropriate for raw meat. Helium flush reduced oxidative changes in cooked meat during sample holding time but was not able to stop oxidative changes in meat after 160 min sample holding. A combination of helium flush and oxygen absorber was effective in preventing volatiles production in cooked meat for over 20 h of sample holding at 4 degrees C.
منابع مشابه
Automated dynamic headspace/GC-MS analyses affect the repeatability of volatiles in irradiated Turkey.
Although a dynamic headspace/gas chromatography-mass spectrometry (DH/GC-MS) method is an effective tool for determining volatiles of irradiated turkey meat, the profile of volatiles may be changeable depending upon the availability of oxygen in the sample vial and sample holding time before purge. The objective of this study was to evaluate the effects of helium flushing and sample holding tim...
متن کاملFat Reduces Volatiles Production in Oil Emulsion System Analyzed by Purge-and-Trap Dynamic Headspace/Gas Chromatography
Release of volatiles in oil emulsion systems containing various fat contents was determined using purge-and-trap dynamic headspace/gas chromatography. Oil emulsions were prepared using 0, 0.5, 1, 2, 4, or 8% oil, and a standard mixture was prepared using hydrocarbons, aldehydes, ketones, and alcohols. Fat content in oil emulsions reduced the volatility of added volatile standards, and the amoun...
متن کاملAutomated Dynamic Headspace/GC-MS Analyses Affects the Repeatability of Volatiles in Irradiated Turkey
متن کامل
Benefits and Limitations of Static Headspace and Purge-and-Trap for the Analysis of VOCs
Static headspace analysis can provide reasonably good sensitivity for halogenated hydrocarbons and aromatic compounds. But USEPA Method 524.2 Revision 4 requires the evaluation of several analytes containing different functional groups such as ketones, ethers, and esters. Such compounds can be particularly difficult to analyze at low concentration using static headspace due to the affinity of p...
متن کاملThe Use of a Multi Purpose Sampler for Headspace GC-MS Analysis of Volatile Organic Compounds in Human Urine
A multi purpose sampler (Gerstel MPS), designed for liquid large volume, gaseous and headspace samples was tested for its suitability in the GC-MS analysis of organic volatiles in human urine. Headspace sampling with a volume, temperature and speed controlled gas tight syringe was combined with a temperature controlled cold injection system for cold trapping, enrichment and focussing of analyte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of agricultural and food chemistry
دوره 47 7 شماره
صفحات -
تاریخ انتشار 1999