Oxygen-15-water PET assessment of muscular blood flow in peripheral vascular disease.

نویسندگان

  • W Burchert
  • S Schellong
  • J van den Hoff
  • G J Meyer
  • K Alexander
  • H Hundeshagen
چکیده

UNLABELLED To assess quantitatively regional nutritive muscular blood flow in patients with peripheral vascular disease (PVD), we evaluated the utility of PET with 15O-water. METHODS Eight healthy volunteers and 16 patients with angiographically proven PVD were studied. Regional blood flow of the calf was measured with 15O-water PET during rest, after intra-arterial infusion of prostaglandin E1 and during ergometry. The studies were quantified using a one tissue compartment model. RESULTS Normalized mean tracer uptake from 15-60 sec correlated closely (r = 0.98) with absolute blood flow. Scan times longer than 90 sec were required to determine blood flow reliably. The flow values were overestimated by 2% if arterial blood volume was neglected or if the input function delay was corrected globally for parametric imaging. Mean blood flow of calf muscles at rest did not differ significantly between patients (0.017 +/- 0.006 ml/min/ml) and control subjects (0.018 +/- 0.010 ml/min/ml). In PVD patients, blood flow increased by 100% after intra-arterial infusion of PGE1 in the respective leg. In the control subjects, average flow increased by a factor of six during exercise. The increase was more pronounced in the extensor muscles (0.182 +/- 0.031 ml/min/ml) than in flexor muscles (0.121 +/- 0.045 ml/min/ml). Due to the specific type of ergometry, superficial flexors exhibited higher flow values than the profound ones. CONCLUSION PET with 15O-water enables reliable determination of regional nutritive skeletal muscle blood flow for research and clinical applications in patients with PVD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between regional myocardial oxygenation and perfusion in patients with coronary artery disease: insights from cardiovascular magnetic resonance and positron emission tomography.

BACKGROUND It is recognized that the interplay between myocardial ischemia, perfusion, and oxygenation in the setting of coronary artery disease (CAD) is complex and that myocardial oxygenation and perfusion may become dissociated. Blood oxygen level-dependent (BOLD) cardiovascular magnetic resonance (CMR) has the potential to noninvasively measure myocardial oxygenation, whereas positron emiss...

متن کامل

Quantitative Analysis of Coronary Endothelial Function with Generator-produced Rubidium- 82 Pet -comparison with Oxygen 15-labeled Water Pet

Purpose Endothelial dysfunction is the earliest abnormality in the development of coronary atherosclerosis. Rubidium-82 (82 Rb) is a generator-produced positron emission tomography (PET) myocardial perfusion tracer that is becoming more widely used. We aimed to develop a method for quantitative assessment of coronary endothelial function using the myocardial blood flow (MBF) response during a c...

متن کامل

Comparison of clinical non-commercial tools for automated quantification of myocardial blood flow using oxygen-15-labelled water PET/CT.

AIMS Absolute quantification of myocardial blood flow (MBF) with (15)O-water cardiac positron emission tomography (PET)/CT has recently demonstrated to hold promising diagnostic value for the detection of coronary artery disease (CAD). However, methodological differences in utilized analysis software packages (SP) could affect generated MBF values, potentially prohibiting widespread clinical ap...

متن کامل

Rapid quantitative CBF and CMRO2 measurements from a single PET scan with sequential administration of dual 15O-labeled tracers

Positron emission tomography (PET) with (15)O tracers provides essential information in patients with cerebral vascular disorders, such as cerebral blood flow (CBF), oxygen extraction fraction (OEF), and metabolic rate of oxygen (CMRO(2)). However, most of techniques require an additional C(15)O scan for compensating cerebral blood volume (CBV). We aimed to establish a technique to calculate al...

متن کامل

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 1997