Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms.

نویسندگان

  • Gádor Cantón
  • David I Levy
  • Juan C Lasheras
  • Peter K Nelson
چکیده

OBJECT The goal of this study was to quantify the reduction in velocity, vorticity, and shear stresses resulting from the sequential placement of stents across the neck of sidewall cerebral aneurysms. METHODS A digital particle image velocimetry (DPIV) system was used to measure the pulsatile velocity field within a flexible silicone sidewall intracranial aneurysm model and at the aneurysm neck-parent artery interface in this model. The DPIV system is capable of providing an instantaneous, quantitative two-dimensional measurement of the velocity vector field of "blood" flow inside the aneurysm pouch and the parent vessel, and its changes at varying stages of the cardiac cycle. The corresponding vorticity and shear stress fields are then computed from the velocity field data. Three Neuroform stents (Boston Scientific/Target), each with a strut thickness between 60 and 65 microm, were subsequently placed across the neck of the aneurysm model and measurements were obtained after each stent had been placed. The authors measured a consistent decrease in the values of the maximal averaged velocity, vorticity, and shear stress after placing one, two, and three stents. Measurements of the circulation inside the sac demonstrated a systematic reduction in the strength of the vortex due to the stent placement. The decrease in the magnitude of the aforementioned quantities after the first stent was placed was remarkable. Placement of two or three stents led to a less significant reduction than placement of the first stent. CONCLUSIONS The use of multiple flexible intravascular stents effectively reduces the strength of the vortex forming in an aneurysm sac and results in a decrease in the magnitude of stresses acting on the aneurysm wall.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic Effects of Stent Struts versus Straightening of Vessels in Stent-Assisted Coil Embolization for Sidewall Cerebral Aneurysms

BACKGROUND Recent clinical studies have shown that recanalization rates are lower in stent-assisted coil embolization than in coiling alone in the treatment of cerebral aneurysms. OBJECTIVE This study aimed to assess and compare the hemodynamic effect of stent struts and straightening of vessels by stent placement on reducing flow velocity in sidewall aneurysms, with the goal of reducing reca...

متن کامل

Figure 1: Schematic of the Idealized Sidewall Aneurysm Model (left) and Camera and Fluoroscopic Shots of the Five Devices Implanted in Silicone Models

Brain aneurysms are abnormal ballooning of intracranial arteries which when left untreated may result in fatal outcome for the patients. Neurovascular stents have been used extensively in stent-assisted coiling treatment of aneurysms. Treatment with flow diverters (low porosity, fine-mesh stents) is used for complicated aneurysm geometries not amenable to coiling. Angiographic analysis with mat...

متن کامل

Balloon-assisted coil placement in wide-neck bifurcation aneurysms by use of a new, compliant balloon microcatheter.

Two types of balloon are usually employed to perform balloon-assisted coil placement in cerebral aneurysms: oval, guide-dependent balloons for sidewall aneurysms and round balloons for bifurcation aneurysms. We report on the use of a new, more compliant, guide-dependent oval balloon microcatheter to seal wide-neck bifurcation aneurysms with coils during endovascular occlusion.

متن کامل

Closed-Cell Stent-Assisted Coiling of Intracranial Aneurysms: Evaluation of Changes in Vascular Geometry Using Digital Subtraction Angiography

BACKGROUND Stent-assisted coil embolization (SACE) plays an important role in the treatment of intracranial aneurysms. The purpose of this study was to investigate geometrical changes caused by closed-cell design stents in bifurcation and sidewall aneurysms. METHODS 31 patients with 34 aneurysms underwent SACE with closed-cell design stents. Inflow angle α, determined by aneurysm neck and aff...

متن کامل

Balloons and Stents in the Endovascular Treatment of Cerebral Aneurysms: Vascular Anatomy Remodeled

Wide-neck intracranial aneurysms were originally thought to be either untreatable or very challenging to treat by endovascular means because of the risk of coil protrusion into the parent vessel. The introduction of the balloon remodeling technique (BRT) and later stents specifically designed for intracranial use has progressively allowed these lesions to be endovascularly treated. BRT and sten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 103 5  شماره 

صفحات  -

تاریخ انتشار 2005