Navigator based FUS Transducer Tracking without the micro-RF coil setup
نویسنده
چکیده
Introduction: The ability to track the location of the ultrasound transducer is of utmost significance in various new Magnetic Resonance guided Focused Ultrasound (MRgFUS) applications such as in pain palliation of bone metastases and prostate tumor treatment. The ultrasound transducer is generally monitored using a micro-RF coil setup shown in Figure 1. The tracking of micro RF-coils was first introduced in [1] and in the MRgFUS applications they are embedded on the transducer and their positions are estimated to track the location of the transducer. The success of these applications is highly dependent upon the quality of the micro-RF coil position measurements, which could be erroneous if the signal from the surrounding anatomy is not properly suppressed. In this work, a kspace based novel technique is described to demonstrate the feasibility of transducer tracking without the microRF coil setup, which would be amenable for the new MRgFUS applications.
منابع مشابه
Preclinical Evaluation of an MR-EP Suite including an MR-EP Navigator and Dedicated MR-EP Catheters
Introduction: Cardiac arrhythmias, e.g. atrial fibrillation and ventricular tachycardia, are increasingly treated by electrophysiological (EP) interventions [1]. Applying MR for guiding these interventions offers advantages like 3D visualization of the cardiac soft tissue in relation to the catheter, visualization of the treatment effect and absence of ionizing radiation [2,3]. The step towards...
متن کاملOpen-source, small-animal magnetic resonance-guided focused ultrasound system
BACKGROUND MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing n...
متن کاملAn Alternative Concept for Non-Sequence Interfering, Contact-free Respiration Monitoring
Introduction Respiratory motion is a challenging problem in MRI, especially in abdominal and cardiac imaging. Appropriate motion detection and correction is needed to cope with this problem, and to improve diagnostic image quality. The respiratory navigator [1] is an existing MR based motion detection method and thus contact-free, it provides very good accuracy but has several disadvantages: th...
متن کاملMechanical Focal Spot Scanning with a Robotic Assistance System for MRgFUS Therapy
Introduction Focused ultrasound surgery (FUS) is a completely non-invasive technique to ablate pathogenic tissue targets. FUS treatment highly benefits from therapy guidance by MRI with its ability for continuous non-invasive temperature monitoring [1]. However, the implementation of a FUS therapy system into an MR scanner is still challenging and demands a combination of complex technologies. ...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کامل