Solution mixing and the emission of light in flow-cells for chemiluminescence detection.

نویسندگان

  • Jessica M Terry
  • Elizabeth M Zammit
  • Teo Slezak
  • Neil W Barnett
  • Don C Olson
  • Duane K Wolcott
  • Donna L Edwards
  • Paul S Francis
چکیده

Constructing flow-through reactors for chemiluminescence detection by machining channels into polymer disks has enabled the exploration of new configurations and materials that can improve signal intensity beyond that attainable with the traditional coiled-tubing design. Several approaches to merge reactant solutions were examined: an intersection, chamber or deeper well in the centre of a serpentine configuration flow-cell (directly in front of a photomultiplier tube), or a confluence point outside the detection zone. For several analytically useful, rapid chemiluminescence reactions, the single-inlet flow-cell with external Y-piece was most suitable, but for others (such as KMnO(4)/Mn(II) with morphine, and [Ir(f-ppy)(2)BPS](-) with fluoroquinolones) the dual-inlet configuration provided greater signals. The introduction of central mixing zones with larger widths than the channel reduced the chemiluminescence response. The reversing turns of a serpentine channel promote efficient mixing and greater chemiluminescence intensities than a spiral channel, but increasing the sharpness of the turns created areas of poor solution flow and decreased the chemiluminescence response. Teflon disks impregnated with glass microspheres increased the chemiluminescence signals by 13%-17%, due to the greater reflection of stray light towards the photodetector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission

Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...

متن کامل

The Study of Chemiluminescence of Acridinium Ester in Presence of Rhodamin B as a Fluorescer

The reaction of hydrogen peroxide and  pheny -9-acridinecarboxylate in the presence of rhodamin B as a fluorophore leads to the emission of either bright blue light  or bright red light, depending on the structure of fluorescer and reaction conditions. The light emitter responsible for the Chemi Luminescence (CL) reaction is acridone and that the blue light produced with out the fluorescers...

متن کامل

Passive micromixer for luminol-peroxide chemiluminescence detection.

This paper reports a microchip with an integrated passive micromixer based on chaotic advection. The micromixer with staggered herringbone structures was used for luminol-peroxide chemiluminescence detection. The micromixer was examined to assess its suitability for chemiluminescence reaction. The relationship between the flow rate and the location of maximum chemiluminescence intensity was inv...

متن کامل

Flow-injection chemiluminescence determination of isoniazid using on-line electrogenerated BrO2 as an oxidant

By designing a novel electrolytic flow cell, the strong oxidant BrO2 was electrogenerated on-line in KBr solution and its concentration could be readily adjusted on-line with the flow-injection technique and an electrochemical method. The chemical reaction between BrO2 and luminol in alkaline medium is accompanied by weak emission of light due to chemiluminescence (CL). It was found that the is...

متن کامل

Chemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System

A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 136 5  شماره 

صفحات  -

تاریخ انتشار 2011