A Rapid, Quantitative Method to Characterize The Human Lymphocyte Concentration for Automated High-Throughput Radiation Biodosimetry.

نویسندگان

  • Yanping Xu
  • Helen C Turner
  • Guy Garty
  • David Brenner
چکیده

We have developed a Quantitative Light Absorption Analysis (QLAA) method to rapidly estimate human lymphocyte concentrations isolated from small volumes of whole blood. Measurements of the light absorption analysis were calibrated for lymphocyte concentration levels using a hemocytometer. To validate the QLAA system, blood samples were collected from 17 healthy donors and lymphocyte absorption measurements were directly compared with the manual microscope counting. The results showed that lymphocyte measurements obtained using the QLAA system were comparable with the manually scored lymphocyte counts but with measurements taken in seconds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adapting the γ-H2AX assay for automated processing in human lymphocytes. 1. Technological aspects.

The immunofluorescence-based detection of γ-H2AX is a reliable and sensitive method for quantitatively measuring DNA double-strand breaks (DSBs) in irradiated samples. Since H2AX phosphorylation is highly linear with radiation dose, this well-established biomarker is in current use in radiation biodosimetry. At the Center for High-Throughput Minimally Invasive Radiation Biodosimetry, we have de...

متن کامل

Adapting the c-H2AX Assay for Automated Processing in Human Lymphocytes. 1. Technological Aspects

The immunofluorescence-based detection of c-H2AX is a reliable and sensitive method for quantitatively measuring DNA double-strand breaks (DSBs) in irradiated samples. Since H2AX phosphorylation is highly linear with radiation dose, this wellestablished biomarker is in current use in radiation biodosimetry. At the Center for High-Throughput Minimally Invasive Radiation Biodosimetry, we have dev...

متن کامل

The RABiT: a rapid automated biodosimetry tool for radiological triage. II. Technological developments.

PURPOSE Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. MATERIALS AND METHODS The RABiT analyses fingerstick-derived blood samples...

متن کامل

Fast image analysis for the micronucleus assay in a fully automated high-throughput biodosimetry system.

The development of, and results from an image analysis system are presented for automated detection and scoring of micronuclei in human peripheral blood lymphocytes. The system is part of the Rapid Automated Biodosimetry Tool, which was developed at the Center for High-Throughput Minimally Invasive Radiation Biodosimetry for rapid radiation dose assessment of many individuals based on single fi...

متن کامل

Development of a Robotically-based Automated Biodosimetry Tool for High-throughput Radiological Triage

To provide the best opportunities for life-saving interventions in the event of a radiological or nuclear threat, there is an urgent need to improve the speed and efficiency of biodosimetric assays for triage and therapy. A rapid automated biodosimetric assay tool used to assess thousands of individual radiation exposure doses is helpful to curb mass panic, and to conserve limited medical resou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical engineering research

دوره 2 1  شماره 

صفحات  -

تاریخ انتشار 2013