Radiation dose reduction in CT-guided periradicular injections in lumbar spine: Feasibility of a new institutional protocol for improved patient safety
نویسندگان
چکیده
BACKGROUND Image guided spinal injections are successfully used in the management of low back pain and sciatica. The main benefit of CT-guided injections is the safe, fast and precise needle placement, but the radiation exposure remains a serious concern. The purpose of the study was to test a new institutional low-dose protocol for CT-guided periradicular injections in lumbar spine to reduce radiation exposure while increasing accuracy and safety for the patients. METHODS We performed a retrospective analysis of a prospective database during a 4-month period (Oct-Dec 2011) at a German University hospital using a newly established low-dose-CT-protocol for periradicular injections in patients suffering from lumbar disc herniation and nerve root entrapment. Inclusion criteria were acute or chronic nerve root irritation due to lumbar disc hernia, age over 18, compliance and informed consent. Excluded were patients suffering from severe obesity (BMI > 30), coagulopathy, allergy to injected substances, infection and non-compliant patients. Outcome parameters consisted of the measured dose length product (mGycm2), the amount of scans, age, gender, BMI and the peri-interventional complications. The results were compared to 50 patients, treated in the standard-interventional CT-protocol for spinal injections, performed in June-Oct 2011, who met the above mentioned inclusion criteria. RESULTS A total amount of 100 patients were enrolled in the study. A significant radiation dose reduction (average 85.31%) was achieved using the institutional low-dose protocol compared to standard intervention mode in CT-guided periradicular injections in lumbar spine. Using the low-dose protocol did not increase the complications rate in the analyzed cohort. CONCLUSIONS Low-dose-CT-protocols for lumbar perineural injections significantly reduce the exposure to radiation of non-obese patients without an increase of complications. This increases long-time patient safety of stochastic radiation effects.
منابع مشابه
Effective radiation dose reduction in computed tomography-guided spinal injections: a prospective, comparative study with technical considerations
Despite the good general patient acceptance, high patient comfort, safety and precision in the needle placement, exposure to radiation in computed tomography (CT)-guided spinal interventions remains a serious concern, and is often used to argue against its use. The aim of this study was to determine the technical possibilities of reducing the radiation dose in CT-guided epidural and periradicul...
متن کاملEffective Dose of CT-Guided Epidural and Periradicular Injections of the Lumbar Spine: A Retrospective Study
Spinal injection procedures can be performed blindly or, more accurately, with fluoroscopic or computed tomography (CT) guidance. Radiographic guidance for selective nerve root blocks and epidural injections allows an accurate needle placement, reduces the procedure time and is more secure for the patient, especially in patients with marked degenerative changes and scoliosis, resulting in a nar...
متن کاملReal-time sonographic imaging for periradicular injections in the lumbar spine: a sonographic anatomic study of a new technique.
OBJECTIVE We conducted this study to develop a sonographically guided approach to the spinal nerve of the lumbar spine and to assess its feasibility and accuracy by means of computed tomography (CT). METHODS Fifty sonographically guided approaches at 5 levels (L1-S1) were performed on 5 embalmed cadavers, which were positioned prone. The spinal nerves of the lumbar spine were shown under sono...
متن کاملReducing patient radiation dose during CT-guided procedures: demonstration in spinal injections for pain.
BACKGROUND AND PURPOSE CT guidance may improve precision for diagnostic and therapeutic spinal injections, but it can increase patient radiation dose. This study examined the impact of reducing tube current on patient radiation exposure and the technical success for these procedures, by using axial acquisitions for short scan lengths and eliminating nonessential imaging. MATERIALS AND METHODS...
متن کاملتخمین میزان پرتوگیری بیماران از تصویربرداری رادیوگرافی در بیمارستان های ارجاعی دولتی شهر ساری
Background and purpose: Estimation of the risks of radiation would be possible by identifying the dose received. Introducing the dose level from diagnostic procedures can be effective in reducing the patient dose, improving the quality of treatment, and increasing the safety of patients and staff. This study evaluated patient entrance surface dose (ESD), effective dose, and cumulative dose from...