Arthroscopic biceps tenodesis: a new technique using bioabsorbable interference screw fixation.
نویسندگان
چکیده
PURPOSE To report a new technique of arthroscopic biceps tenodesis using bioabsorbable interference screw fixation and the early results. TYPE OF STUDY Prospective, nonrandomized study. METHODS TECHNIQUE The principle of arthroscopic biceps tenodesis is simple: after biceps tenotomy, the tendon is exteriorized and doubled on a suture; the biceps tendon is then pulled into a humeral socket (7 or 8 mm x 25 mm) drilled at the top of the bicipital groove, and fixed using a bioabsorbable interference screw (8 or 9 mm x 25 mm) under arthroscopic control. PATIENTS 43 patients treated with this technique between 1997 and 1999 were followed-up for at least 1 year. The technique was indicated in 3 clinical situations: (1) with arthroscopic cuff repair (3 cases), (2) in case of isolated pathology of the biceps tendon with an intact cuff (6 cases), and (3) as an alternative to biceps tenotomy in patients with massive, degenerative and irreparable cuff tears (34 cases). The biceps pathology was tenosynovitis (4 cases), prerupture (15 cases), subluxation (11 cases), and luxation (13 cases). RESULTS The absolute Constant score improved from 43 points preoperatively to 79 points at review (P <.005). There was no loss of elbow movement and biceps strength was 90% of the strength of the other side. Two patients, operated on early in the series, presented with a rupture of the tenodesis. In both cases the bicipital tendon was very friable and the diameter of the screw proved to be insufficient (7 mm). No neurologic or vascular complications occurred. CONCLUSIONS Arthroscopic biceps tenodesis using bioabsorbable screw fixation is technically possible and gives good clinical results. This technique can be used in cases of isolated pathologic biceps tendon or a cuff tear. A very thin, fragile, almost ruptured biceps tendon is the technical limit of this arthroscopic technique.
منابع مشابه
Biomechanical comparison of intramedullary cortical button fixation and interference screw technique for subpectoral biceps tenodesis.
PURPOSE The purpose of this study was to biomechanically evaluate a new technique of intramedullary cortical button fixation for subpectoral biceps tenodesis and to compare it with the interference screw technique. METHODS We compared intramedullary unicortical button fixation (BicepsButton; Arthrex, Naples, FL) with interference screw fixation (Bio-Tenodesis screw; Arthrex) for subpectoral b...
متن کاملArthroscopic-assisted biceps tenodesis for ruptures of the long head of biceps brachii: The cobra procedure.
A number of open procedures have been presented in the literature that described the repair of the ruptured long head of biceps brachii (LHBB). Although arthroscopic biceps tenodesis techniques have been used to address partial tears or subluxation of the biceps, no arthroscopic technique to assist in the treatment of complete retracted ruptures of the LHBB has been described. This article desc...
متن کاملInterference Screw vs. Suture Anchor Fixation for Open Subpectoral Biceps Tenodesis: Does it Matter?
BACKGROUND Bioabsorbable interference screw fixation has superior biomechanical properties compared to suture anchor fixation for biceps tenodesis. However, it is unknown whether fixation technique influences clinical results. HYPOTHESIS We hypothesize that subpectoral interference screw fixation offers relevant clinical advantages over suture anchor fixation for biceps tenodesis. STUDY DES...
متن کاملArthroscopic Biceps Tenodesis Using Interference Screw Fixation in the Bicipital Groove
Arthroscopic repair of the long head of the biceps (LHB) is performed to treat various biceps pathologies yet the choice between tenotomy or tenodesis remains controversial. Although tenotomy is simpler and quicker, tenodesis results in fewer complications, and there are several techniques available using various fixation devices and sites. This Technical Note describes an all-arthroscopic, sup...
متن کاملArthroscopic tenodesis of the long head of the biceps.
The long head of the biceps (LHB) is commonly implicated in shoulder pathology due to its anatomic course and intimacy with the rotator cuff and superior labrum of the glenoid. Treatment of tendinosis of the LHB may be required secondary to partial thickness tears, instability/subluxation, associated rotator cuff tears, or SLAP (superior labrum, anterior to posterior) lesions. Treatment options...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
دوره 18 9 شماره
صفحات -
تاریخ انتشار 2002