Electrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode.

نویسندگان

  • Zong Dai
  • Jin Chen
  • Feng Yan
  • Huangxian Ju
چکیده

A sensor based on thionine monolayer modified gold electrode for determination of carcinoembryonic antigen (CEA) in human serum is proposed. The sensor is prepared by covalently binding thionine to a cysteamine self-assembled monolayer with p-phthaloyl chloride as a linkage, which gives a surface coverage of 8.97+/-3.28 x 10(-12)mol/cm(2) for thionine. The electrochemistry of the immobilized thionine displays a surface-controlled electrode process with an average electron transfer rate constant of 1.47+/-0.84 s(-1). Based on an electrochemical enzyme-linked immunoassay by using the immobilized thionine as an electron transfer mediator between the electrode and the horseradish peroxidase (HRP) labeled anti-CEA antibody, a calibration curve with two linear ranges from 0.6 to 17 and 17 to 200 ng/mL and a detection limit of 0.2 ng/mL for CEA determination is obtained in pH 4.2 PBS containing 2.0 mmol/L H(2)O(2) and 0.5 mol/L NaCl. The sensor shows a good accuracy. The precision and reproducibility are acceptable with the intra-assay CV of 4.9% and 5.9% at 10 and 100 ng/mL CEA concentrations, respectively, and the inter-assays CV of 7.8% at 100 ng/mL CEA. The response of thionine modified electrode shows only 1.6% decrease after 100 replicate measurements and the storage stability is acceptable in a pH 7.0 PBS at 4 degrees C for 1 week. The method avoids the addition of electron transfer mediator to the solution, thus is much simpler. The proposed method would be valuable for the diagnosis and monitoring of carcinoma and its metastasis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An aptasensor based on electrosynthesized conducting polymers, Cu2O–carbon dots and biosynthesized gold nanoparticles, for monitoring carcinoembryonic antigen

Current work proposes an inimitable composite, with great electrical conductivity and quite enhanced surface area, (including conducting polymers (poly (cathechol)), Cu2O–carbon dots and green synthesized gold nanoparticles) for detecting acute carcinoembryonic antigen. At current work, the electropolymerization was offered instead of enzyme-catalyzed polymerization of poly (catechol). <b...

متن کامل

Highly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide

A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...

متن کامل

Electrochemical immunosensor for carcinoembryonic antigen based on antigen immobilization in gold nanoparticles modified chitosan membrane.

A disposable electrochemical immunosensor for carcinoembryonic antigen (CEA) was proposed based on the antigen immobilized in a colloidal gold nanoparticles modified chitosan membrane on the surface of an indium-tin oxide (ITO) electrode. The different membranes were characterized by scanning electron microscope and electrochemical methods. Based on a competitive immunoassay format, the immobil...

متن کامل

Aminothiophenol Furfural Self-assembled Gold Electrode Sensor for Determination of Dopamine in Pharmaceutical Formulations

A new Schiff base 2-aminothiophenol furfural self assembled monolayer (SAM) has been fabricated on a bare gold electrode as a novel sensor for determination of dopamine. Electrochemical impedance spectroscopywas utilized to investigate the properties of the Au 2-aminothiophenol furfural self assembled monolayermodified electrode (Au ATF SAM-ME) using the [Fe(CN)6]3-/4- redox couple. The electro...

متن کامل

Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen.

A novel immunosensor for rapid separation-free determination of carcinoembryonic antigen (CEA) in human serum is proposed. The immunosensor is prepared by co-immobilizing thionine and horseradish peroxidase (HRP)-labeled CEA antibody on a glassy carbon electrode (GCE) through covalently binding them to GCE with a glutaraldehyde (GA) linkage. The electrochemical behavior of the immobilized thion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer detection and prevention

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 2005