A Comparison between Conductive and Infrared Devices for Measuring Mean Skin Temperature at Rest, during Exercise in the Heat, and Recovery
نویسندگان
چکیده
PURPOSE Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. METHODS Mean skin temperature ([Formula: see text]) was assessed in thirty healthy males during 30 min rest (24.0 ± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery (24.0 ± 1.3°C, 56 ± 9%). [Formula: see text] was assessed at four sites using two conductive devices (thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). RESULTS Bland-Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of [Formula: see text] found significant differences (p < 0.05) between thermistors and both infrared devices during resting conditions, and significant differences between the thermistors and all other devices tested during exercise in the heat and recovery. CONCLUSIONS These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring [Formula: see text] in the presence of, or following, metabolic and environmental induced heat stress.
منابع مشابه
Does the technique employed for skin temperature assessment alter outcomes? A systematic review.
Skin temperature is an important physiological measure that can reflect the presence of illness and injury as well as provide insight into the localised interactions between the body and the environment. The aim of this systematic review was to analyse the agreement between conductive and infrared means of assessing skin temperature which are commonly employed in in clinical, occupational, spor...
متن کاملطراحی و ساخت جلیقه خنککننده از مواد تغییر فاز دهنده و ارزیابی کارایی آن در کاهش استرین گرمایی تحت شرایط آزمایشگاهی
Introduction: Water and paraffin are well-known phase change materials used in the manufacturing of cooling vests. The present study was conducted to design and make a cooling vest using commercial paraffin compounds and ice and to then examine their effect on thermal strain parameters in hot climate conditions in a climate chamber. Materials and Methods: A cooling vest was first made with p...
متن کاملEffects of clothing ventilation openings on thermoregulatory responses during exercise
The effect of clothing openings on thermoregulatory responses of wearers during a treadmill exercise in controlled laboratory conditions has been studied. Nine short sleeved T-shirts with varying design of clothing openings at neck and hem have been designed, and the test is performed on six males, considering 10min of standing rest, 30min of running at 55% of VO2max followed by 10min of rest. ...
متن کاملBody temperature and cold sensation during and following exercise under temperate room conditions in cold‐sensitive young trained females
We evaluated cold sensation at rest and in response to exercise-induced changes in core and skin temperatures in cold-sensitive exercise trained females. Fifty-eight trained young females were screened by a questionnaire, selecting cold-sensitive (Cold-sensitive, n = 7) and non-cold-sensitive (Control, n = 7) individuals. Participants rested in a room at 29.5°C for ~100 min after which ambient ...
متن کاملبررسی یک استراتژی مداخلهای خنککننده برای کاهش استرین حرارتی ناشی از لباس حفاظتی آتشنشانان
Introduction: Protective clothes are among the basic needs of firefighters against their occupational risks. Combination of heat stress effects caused by muscle activation and protective clothing, result in a high level of strain in the regulating system of body temperature. The aim of this study was to evaluate the practical cooling method of hand and forearm immersion in water. Methods: In...
متن کامل