The Impact of Roller Pump vs. Centrifugal Pump on Homologous Blood Transfusion in Pediatric Cardiac Surgery.
نویسندگان
چکیده
Centrifugal pumps are considered to be less destructive to blood elements (1) when compared to roller pumps. However, their large prime volumes render them unsuitable as arterial pumps in heart lung machine (HLM) circuitry for children. In November of 2014, the circuit at Arnold Palmer Hospital, a Biomedicus BP-50 with kinetic assist venous drainage (KAVD) and 1/4″ tubing was converted to a roller pump in the arterial position with gravity drainage. Vacuum-assisted venous drainage (VAVD) was mounted on the HLM as a backup, but not used. Tubing was changed to 3/16″ in the arterial line in patients <13 kg. A retrospective study with a total of 140 patients compared patients placed on cardiopulmonary bypass (CPB) with Biomedicus centrifugal pumps and KAVD (Centrifugal Group, n = 40) to those placed on CPB with roller pumps and gravity drainage (Roller Group, n = 100). Patients requiring extra-corporeal membrane oxygenation (ECMO)/cardio-pulmonary support (CPS) or undergoing a hybrid procedure were excluded. Re-operation or circulatory arrest patients were not excluded. Prime volumes decreased by 57% from 456 ± 34 mL in the Centrifugal Group to 197 ± 34 mL in the Roller Group (p < .001). There was a corresponding increase in hematocrit (HCT) of blood primes and also on CPB. Intraoperative homologous blood transfusions also decreased 55% from 422 mL in the Centrifugal Group to 231 mL in the Roller Group (p < .001). The Society of Thoracic Surgeons--European Association for Cardio-Thoracic Surgery (STAT) categorized intubation times and hospital length of stay (LOS) for all infants showed a trend toward reduction, but was not statistically significant. Overall mortality was 5% utilizing the centrifugal configuration and 0% in the roller pump cohort. We demonstrated that the transition to roller pumps in the arterial position of the HLM considerably reduced our priming volume and formed a basis for a comprehensive blood conservation program. By maintaining higher HCTs on CPB, we were able to reduce intraoperative homologous blood transfusions.
منابع مشابه
Adult cardiac surgery outcomes: role of the pump type.
OBJECTIVE This study was carried out to evaluate whether the type of pump used for cardiopulmonary bypass (CPB; roller vs. centrifugal) can affect mortality or the neurological outcomes of adult cardiac surgery patients. METHODS Between 1994 and June 1999, 4000 consecutive patients underwent coronary and/or valve surgery at our hospital; of these, 2213 (55.3%) underwent surgery with centrifug...
متن کاملOff-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery, prospective cohort study
Introduction: Coronary artery bypass grafting is a surgical operation that bypasses atherosclerotic coronary vessels and restores blood flow to the ischemic zone of hearts. And two different conventional methods are ON-pump CABG, and Off-pump CABG. Altogether, the efficacy and safety of these two types of surgical procedures are still under debate. In this study, we aim to com...
متن کاملHistory of extracorporeal circulation: the invention and modification of blood pumps.
The first roller pump was patented in 1855 by Porter and Bradley and was hand operated. A modification first named "surgical pump", designed and manufactured by E. E. Allen in 1887, was intended for direct blood transfusion. Truax, who also distributed and promoted the Allen pump with one roller, developed the first double roller pump in 1899. In the following decades, several researchers, incl...
متن کاملEffects of cell saver autologous blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing cardiac surgery on- versus off-cardiopulmonary bypass: a randomised trial.
OBJECTIVE Off-pump CABG is potentially associated with reduced intraoperative blood loss and homologous blood transfusion in comparison to on-pump CABG. In this randomised controlled study we investigated the effects of autologous cell saver blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing CABG on- versus off-CPB. METHODS Eighty patients wer...
متن کاملCentrifugal pump and reduction of neurological risk in adult cardiac surgery.
This study was performed to assess if the kind of pump used for CPB (roller vs. centrifugal) can influence neurological outcomes of adult cardiac surgery patients. Between 1994 and 1998, 3438 patients underwent coronary and/or valve surgery at our hospital; of these, 1805 (52.5%) underwent surgery with the use of a centrifugal pump, and 1633 (47.5%) were operated with a roller pump. The effect ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 49 1 شماره
صفحات -
تاریخ انتشار 2017