Improved accuracy in flow mapping of congenital heart disease using stationary phantom technique

نویسندگان

  • Thomas A Miller
  • Andrew B Landes
  • Adrian M Moran
چکیده

BACKGROUND Flow mapping by cardiovascular magnetic resonance has become the gold standard for non-invasively defining cardiac output (CO), shunt flow and regurgitation. Previous reports have highlighted the presence of inherent errors in flow mapping that are improved with the use of a stationary phantom control. To our knowledge, these studies have only been performed in healthy volunteers. RESULTS We analyzed the variation in flow measurements made with and without stationary phantom correction in 31 patients with congenital heart disease. Variation in stroke volume (SV) measurements was seen in all vessels across all patient groups. The variation was largest when analyzing the right ventricular outflow tract (RVOT), with a range of absolute differences in SV from 0.2 to 70 ml and in CO from 0.02 to 4.8 L/min. In patients with repaired Tetrology of Fallot (ToF), the average ratio of pulmonary to systemic blood flow (Qp:Qs) was 1.18 without and 1.02 with phantom correction. Without performing phantom correction, 23% of the repaired ToF patients were classified as having a residual shunt as compared to 0% when flow mapping was performed with phantom correction. Similarly, in patients with known atrial level shunting (ASD/PAPVR) 20% of patients had no shunt when flow mapping was performed without phantom correction as compared to 0% with phantom correction. In patients with bicuspid aortic valves (BAV), the differences in the regurgitant fraction between measuring flow with and without phantom correction ranged from 0 to 30%, while the regurgitant fraction in the RVOT of ToF patients varied by as much as 31%. CONCLUSION The impact of inherent errors in CMR flow mapping should not be underestimated. While the variation across a population may not display a significant trend, for any individual patient it can be quite large. Failure to correct for such variation can lead to clinically significant misinterpretation of flow data. The use of the stationary phantom correction technique appears to improve accuracy both in normal patients as well as those with congenital heart disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Neonate's Congenital Hypothyroidism Pattern Using Poisson Spatio-temporal Model in Disease Mapping under the Bayesian Paradigm during 2011-18 in Guilan, Iran

Background: Congenital Hypothyroidism (CH) is one of the reasons for mental retardation and defective growth in neonates. It can be treated if it is diagnosed early. The congenital hypothyroidism can be diagnosed using newborn screening in the first days after birth. Disease mapping helps to identify high-risk areas of the disease. This study aimed to evaluate the pattern of CH using the Poisso...

متن کامل

Evaluation of diastolic blood flow dynamic of the left ventricle in dogs with mitral valve regurgitation using vector flow mapping

Mitral valve regurgitation (MVR) is a common valvular disease in dogs. Hydrokinetic evaluation of the blood flow within the ventricles has become possible by vector flow mapping (VFM), which shows the blood flow within the ventricles in vector and vortex flows. Blood flow within the left ventricle of MVR dogs was compared at different stages of MVR and to that of normal dogs. 14 normal dogs and...

متن کامل

X-ray magnetic resonance fusion to internal markers and utility in congenital heart disease catheterization.

BACKGROUND X-ray magnetic resonance fusion (XMRF) allows for use of 3D data during cardiac catheterization. However, to date, technical requirements have limited the use of this modality in clinical practice. We report on a new internal-marker XMRF method that we have developed and describe how we used XMRF during cardiac catheterization in congenital heart disease. METHODS AND RESULTS XMRF w...

متن کامل

High-resolution multi-breath-held 3D volumetric T1 mapping acquisition: analysis of volume measurements of small structures using a respiratory motion phantom

Background Myocardial T1 mapping is performed using 8-10mm thick slices; however, this is unsuited for accurate quantification of small structures. We propose a novel 3Dpulse-sequence with improved through-plane spatial resolution. In this study, we use a respiratory motion phantom to compare the accuracy and precision of volume measurements made using this 3D-sequence against a reference 2D-te...

متن کامل

Stochastic Model to Find the Triiodothyronine Repletion in Infants during Cardiopulmonary Bypass for Congenital Heart Disease Using Normal Distribution

Cardiopulmonary bypass suppresses circulating thyroid hormone levels. Although acute triiodothyronine repletion has been evaluated in adult patients after cardiopulmonary bypass, triiodothyronine pharmacokinetics and effects have not previously been studied in infants undergoing operations for congenital heart disease. We hypothesized that triiodothyronine deficiency in the developing heart aft...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2009