Difficulties in differentiating the nature of ascites based on ultrasound imaging

نویسندگان

  • Andrzej Smereczyński
  • Katarzyna Kołaczyk
  • Elżbieta Bernatowicz
چکیده

Transabdominal ultrasound not always allows to determine the nature of ascites based solely on its characteristics. AIM The aim of the study was to present difficulties in determining the nature of ascites using transabdominal ultrasonography solely based on extra-organ lesions as well as, after the inclusion of the overall abdominal assessment and the clinical picture. MATERIALS AND METHODS A total of 18 patients with non-neoplastic ascites and 62 patients with neoplastic ascites whose final diagnosis was based on cytological and histopathological findings were evaluated between 2005 and 2015. Abdominal ultrasound was performed to detect the presence of fluid in all accessible spaces, and, additionally, to determine the presence of potential peritoneal tumor implants as well as to evaluate the parietal peritoneum and the greater omentum. Different digital ultrasound machines equipped with 3-6 MHz and linear 7-12 MHz transducers were used in the study. Double-sided Fisher's exact test with statistical significance at p < 0.05 was used for the analysis of the obtained results. RESULTS Statistically significant differences between benign and neoplastic ascites were found for: anechoic peritoneal fluid (<0.0001); fluid and thickened omentum with smooth surface (<0.0001); fluid and thickened omentum with smooth surface and varices (0.01); fluid and thickened omentum with hypoechoic foci (0.049); fluid and thickened omentum with tumor implants (0.009). The inclusion of the overall assessment of abdominal organs and the clinical data allowed for an improvement in ultrasonographic diagnostic accuracy in benign and neoplastic ascites from 83.3% and 67.7% to 94.4% and 93.5%, respectively. CONCLUSIONS When used alone, an assessment of acoustic fluid characteristics and extra-organ peritoneal lesions limits the possibility to differentiate between benign and malignant ascites. These results improve after the inclusion of sonographic assessment of all abdominal organs in combination with clinical data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...

متن کامل

Ultrasonography of immature teratomas: 11 case reports

Background: Ovarian immature teratoma is a very rare type of tumor associated with a high relapse rate and mortality. Correspondingly, early diagnosis is important for effective treatment. The goal of this study was to retrospectively analyze the ultrasound characteristics of 11 cases of immature teratomas. Materials and Methods: Between January 2002 and December 2010, 11 patients were diagnose...

متن کامل

Thoracic Mass Nature Determination; What Modality Is Better in Pediatric Age?

Background The first step in assessing thoracic lesions is chest X-ray, but the optional imaging procedure for the final diagnosis is controversial. We aimed to examine the diagnostic accuracy of imaging modalities in pediatric thoracic masses. <em...

متن کامل

Ultrasonographic Imaging of Reproductive Organ in Indonesian Native Chicken Hen (Gallus Domesticus)

Hen’s native chicken reproductive organ health status evaluation is important for raising Indonesian native chicken in order to support protein supply for people demand. This study aimed to discover the images of Indonesian hen’s native chicken reproductive organ using ultrasonography. There were 18 hens that used in this study and divided into two groups, 15 hens for brightnessmode ultrasonogr...

متن کامل

Adaptive beamforming in row-column addressed arrays for 3D ultrasound imaging

In recent years, to reduce the complexity of implementation, the use of 2D arrays with restricted row-column addressing has been considered for 3D ultrasound imaging. In this paper, two methods of adaptive beamforming based on the minimum variance method are represented in such a way that the computational load is much less than using the full adaptive beamforming method. In both proposed metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017