Evaluation of dual-label simultaneous assays for lutropin and follitropin in serum.

نویسندگان

  • C J Beinlich
  • J A Piper
  • J C O'Neal
  • O D White
چکیده

We evaluated the analytical performance and clinical utility of three dual-label simultaneous assays for lutropin and follitropin by comparison with widely used individual assays for these analytes (Diagnostic Products Corp.; DPC). Of the three assays evaluated, "Cotropin" (Clinetics Corp.) and "Combostat" (Micromedics Systems, Inc.) compared favorably with the DPC assay with respect to recovery, linearity, intra- and inter-assay precision, and sensitivity for lutropin. The third assay evaluated, "Simultropin" (Becton Dickinson Immunodiagnostics), exhibited greater interassay variability for lutropin than did the DPC assay but otherwise compared favorably. Analytically the three assays were similar to one another for follitropin determinations and results compared favorably with those by the DPC assay. Intercorrelation of patients' results obtained with these assays is poor. However, using the same standards with each of the three assays improved intercorrelation of patients' data except for follitropin by Combostat. A universally accepted reference material for immunoassay of lutropin and follitropin is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double-label time-resolved immunofluorometry of lutropin and follitropin in serum.

We describe a procedure for the simultaneous immunofluorometric assay of lutropin and follitropin in human serum, based on the use of monoclonal antibodies and of the fluorescent lanthanides Eu3+ and Tb3+. The alpha-chain-specific antibody was used as a common capture antibody on the surfaces of microtitration strips. The anti-beta-follitropin antibody was labeled with Tb3+, the anti-beta-lutro...

متن کامل

Pregnant mare serum gonadotropin. An in vitro biological characterization of the lutropin-follitropin dual activity.

The interaction of highly purified pregnant mare serum gonadotropin (PMSG or eCG) has been studied in rat and equine testis homogenates. In the rat studies, unlabeled PMSG was shown to possess both high levels of intrinsic follitropin-like and lutropin-like activity when the inhibition of radioiodinated follitropin and lutropin binding by unlabeled PMSG was studied. Radioiodinated PMSG exhibite...

متن کامل

Assessment of the biopotency of follitropin alfa and lutropin alfa combined in one injection: a comparative trial in Sprague-Dawley rats

BACKGROUND The current study was designed to determine if follitropin alfa (recombinant human follicle-stimulating hormone; r-hFSH) and lutropin alfa (recombinant human luteinizing hormone; r-hLH) biopotencies were unchanged by reconstituting in sterile water for injection and mixing prior to injection. METHODS The biopotencies of r-hFSH and r-hLH were determined following injection of female...

متن کامل

Multicenter evaluation of new enzyme-linked immunoassays of follitropin and lutropin in serum or plasma.

Results from a multicenter evaluation of two new enzyme-linked immunosorbent assays [Enzymun-Test for follitropin (FSH) and lutropin (LH)] are presented and compared with results from 11 other commercial immunoassays, radioactive as well as nonradioactive. Enzymun-Test FSH and LH assays are suitable for automated systems and manual applications. The tests were reproducible (CV less than 5%), hi...

متن کامل

Within- and between-subject biological variations of follitropin, lutropin, testosterone, and sex-hormone-binding globulin in men.

The within-subject and between-subject biological variation of the serum concentrations of follitropin, lutropin, sex-hormone-binding globulin, and testosterone; the ratio between the serum concentrations of testosterone and sex-hormone-binding globulin; and the concentration of testosterone in saliva have been studied in a group of 20 men during 12 months. The between-subject coefficients of v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 12  شماره 

صفحات  -

تاریخ انتشار 1985