Iterative multi-channel radio frequency pulse calibration with improving B1 field uniformity in high field MRI
نویسندگان
چکیده
BACKGROUND In high field MRI capable of multi-channel radio frequency (RF) transmission, B 1 shimming is a time-consuming job because conventional B 1 shimming techniques require B 1 mapping for each channel. After acquiring the complex-numbered B 1 field maps, the optimal amplitude and phase of the driving RF pulse are determined for each channel to maximize the B 1 field uniformity in conventional B 1 shimming. However, time-consuming B 1 shimming procedures at the pre-scan may not be tolerated in the clinical imaging in which patient throughput is one of the important factors. METHODS To avoid the time-consuming B 1 mapping, the first spin echo and the stimulated echo were repeatedly acquired in the slice-selective stimulated echo sequence without imaging gradients. A cost function of the amplitudes and phases of the driving RF pulse for every channel was defined in a way that the ratio between the spin echo and stimulated echo amplitudes rapidly converged to √ 2. The amplitude and phase of the driving RF pulse were iteratively modified over the repeating RF pulse sequence so that the cost function was minimized. RESULTS From the finite-difference-time-domain (FDTD) electromagnetic field simulations with a human body model placed in a birdcage coil operating at 3 T, it was observed that the RF pulse calibration with iterative cost function minimization can give improvement of B1 field uniformity as well as flip-angle calibration. The experiments at 3 T also showed improvement of RF field uniformity in the phantom imaging studies. CONCLUSIONS Since the proposed RF pulse calibration is not based on B 1 mapping, the RF pulse calibration time could be much shorter than the B 1-mapping based methods. The proposed method is expected to be a practical substitute for the B 1-mapping-based B 1 shimming methods when long pre-scan time is not tolerable.
منابع مشابه
Whole heart coronary MRA at 3.0T: a comparison between multi and single- RF transmission
Introduction On high field MRI scanners uniform radio frequency (RF) excitation over the entire field-of-view is often challenging with single-channel RF transmit coils. This may cause a reduction of image quality (e.g. shadowing artifacts). This problem is most pronounced in sequences which heavily rely on a homogenous magnetic field, such as steady state free precession (SSFP) sequences, desp...
متن کاملImproved excitation fidelity in cardiac imaging with 2-spoke parallel excitation at 7 Tesla
Background Cardiac MRI may greatly benefit from ultra high field (UHF) providing higher SNR and intrinsic contrast. But shorter RF wavelength yields transmit B1 (B1+) heterogeneity and contrast variations through the heart. These can be addressed by parallel transmission (pTX) using multispoke RF pulses as previously shown in other organs. However, applying pTX in cardiac MRI at 7T is challengi...
متن کاملA Novel Radiofrequency Pulse Design for Improving Flip-angle Uniformity in Ultra-high Field MRI
Purpose The problem of inhomogeneous B1 + fields in high field MRI has previously been addressed by novel or improved RF pulse designs (e.g. sparse spokes [1] and adiabatic pulses [2]) and hardware modifications (e.g. parallel transmit coils [3]). Existing techniques have practical limitations in that B1 + maps must be acquired for a specific imaging slice prior to the design of the RF pulse, S...
متن کاملA comparison of single-channel and multi-channel RF transmit coil for SSFP cine imaging at 3 Tesla
Introduction On high field MRI scanners uniform radio frequency (RF) excitation over the entire field-of-view (FOV) is often challenging with single-channel RF transmit coils. This may cause a reduction of image quality (e.g. shadowing artifacts). This problem is most pronounced in sequences that heavily rely on a homogenous magnetic field, such as steady state free precession (SSFP) sequences....
متن کاملParallel Excitation: Making SENSE of High-Field Body MRI
MR imaging at high B0 field strength presents significant diagnostic opportunities derived from enhancements in SNR, spectral resolution and image contrast. However there are technical challenges that substantially hamper the practice of high-field MRI, including a major one that is related to the exploitation of the radio frequency EM field (B1 field and concomitant E field). As field strength...
متن کامل