Comparison of Specific Femoral Short Stems and Conventional-Length Stems in Primary Cementless Total Hip Arthroplasty.

نویسندگان

  • Young-Soo Shin
  • Dong-Hun Suh
  • Jong-Hoon Park
  • Jeong-Lae Kim
  • Seung-Beom Han
چکیده

There are several reported disadvantages with conventional-length femoral stems in cementless total hip arthroplasty (THA). Therefore, various efforts have been made to develop a specific femoral short stem to improve physiologic bone remodeling at the femoral aspect of a cementless THA. However, there are potential disadvantages with specific femoral short stems, such as malalignment, inadvertent subsidence, and potential proximal femoral fracture. Therefore, the authors quantitatively compared radiographic and clinical outcomes as well as component-specific complications between 2 groups of patients following primary cementless THA. A matched comparison was made between specific femoral short stems (n=50) and conventional-length femoral stems (n=50) in cementless THA procedures performed between January 2008 and January 2012. Patients were matched for age, sex, body mass index, height, surgical approach, and surgeon. No significant differences were found between the 2 groups in mean postoperative radiographic outcomes, functional outcomes, or complications. Both groups showed satisfactory performance at 5-year follow-up. Specific femoral short stems resulted in a higher incidence of malalignment and subsidence and a lower incidence of thigh pain and proximal bone resorption compared with conventional-length femoral stems. Although longer follow-up is required, specific femoral short stems may have clinical and radiographic advantages with equivalent perioperative complications relative to conventional-length femoral stems. However, this technique requires proper patient selection in combination with careful preoperative planning and meticulous surgical technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of cementless femoral stems inserted in varus on functional outcome in primary total hip arthroplasty.

INTRODUCTION Historically, cemented total hip arthroplasty (THA) femoral stems inserted in varus have yielded poor clinical results. Few studies to date have addressed the question of the effects of varus alignment on cementless stems. We conducted a retrospective review of 125 uncemented THA femoral stems implanted by a single surgeon from 1994 to 1999. METHODS We conducted a retrospective r...

متن کامل

Short stem total hip arthroplasty in patients with rheumatoid arthritis.

Total hip arthroplasty (THA) has proven successful in patients with rheumatoid arthritis (RA). Patients with RA often require multiple revisions, and bone conservation is mandatory. A variety of short stems is currently available with mid-term results for osteoarthritis. This retrospective study evaluated mid-term clinical results of short stem THA in a series of patients with RA. Between 2005 ...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Stubby stems: good things come in small packages.

Standard-length porous-coated tapered femoral stems perform exceedingly well in primary total hip arthroplasty (THA) at long-term follow-up. Nevertheless, there are multiple reasons to strongly consider the relatively new concept of short tapered stems. First, there is already a wide variation in the lengths of "standard" components and the ideal length is unknown. The goal of tapered stems is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopedics

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2016