Comparative analysis of numerical and experimental data of orthodontic mini-implants.

نویسندگان

  • Athina Chatzigianni
  • Ludger Keilig
  • Heinz Duschner
  • Hermann Götz
  • Theodore Eliades
  • Christoph Bourauel
چکیده

The purpose of this study was to compare numerical simulation data derived from finite element analysis (FEA) to experimental data on mini-implant loading. Nine finite element (FE) models of mini-implants and surrounding bone were derived from corresponding experimental specimens. The animal bone in the experiment consisted of bovine rib. The experimental groups were based on implant type, length, diameter, and angle of insertion. One experimental specimen was randomly selected from each group and was digitized in a microCT scanner. The FE models consisted of bone pieces containing Aarhus mini-implants with dimensions 1.5 × 7 mm and 1.5 × 9 mm or LOMAS mini-implants (dimensions 1.5 × 7 mm, 1.5 × 9 mm, and 2 × 7 mm). Mini-implants were inserted in two different ways, perpendicular to the bone surface or at 45 degrees to the direction of the applied load. Loading and boundary conditions in the FE models were adjusted to match the experimental situation, with the force applied on the neck of the mini-implants, along the mesio-distal direction up to a maximum of 0.5 N. Displacement and rotation of mini-implants after force application calculated by FEA were compared to previously recorded experimental deflections of the same mini-implants. Analysis of data with the Altman-Bland test and the Youden plot demonstrated good agreement between numerical and experimental findings (P = not significant) for the models selected. This study provides further evidence of the appropriateness of the FEA as an investigational tool in relevant research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resistance to immediate orthodontic loading of surface-treated mini-implants.

OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to orthodontic forces of immediately loaded sandblasted and acid-etched (SAE) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS Two types of mini-implants were used in the tibiae of 44 rabbits; some had an SAE surface and some had machined surfaces....

متن کامل

Treatment of Skeletal Anterior Open Bite Using Absolute Anchorage: A Case Report and Review

 Background and purpose: Skeletal anchorage is a new aid for the correction of moderate anterior open bite. This study aimed at treating moderate anterior open bite using posterior intrusion via mini implants. In addition, a review of studies carried out on open bite correction using absolute anchorage was performed. Materials and methods: The following keywords were used: open bite, camouflag...

متن کامل

Patients' perception of installation, use and results of orthodontic mini-implants.

The purpose of this study was to evaluate patient acceptance and perception of pain with regard to orthodontic mini-implants. The study was conducted on 58 individuals undergoing orthodontic treatment, who had orthodontic mini-implants placed as anchorage devices. Data were collected using a questionnaire containing 6 questions evaluating perception of pain during mini-implant placement and dur...

متن کامل

A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science

The purpose of this literature review was to screen the valuable published articles regarding to the impacts of mini-implants on orthodontic science, briefly. The searching category was performed on the Pubmed using MeSH words such as "dental (mini) implants, orthodontic anchorage procedures, and orthodontic appliances." After preliminary sketch, they were grouped as follow: Those evaluating (a...

متن کامل

Clinical indices for orthodontic mini-implants.

Orthodontic mini-implants were recently developed and have been widely used in clinics. However, loosening of mini-implants, as well as infection and swelling of mucosal tissue at the placement site, are often observed during orthodontic treatment. Thus, clinical indices are greatly needed for the safe use of orthodontic mini-implants. This article presents information on mini-implants and offe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 33 5  شماره 

صفحات  -

تاریخ انتشار 2011