Dose evaluation for skin and organ in hepatocellular carcinoma during angiographic procedure

نویسندگان

  • Daniela D’Alessio
  • Claudia Giliberti
  • Antonella Soriani
  • Livio Carpanese
  • Giuseppe Pizzi
  • Giulio Eugenio Vallati
  • Lidia Strigari
چکیده

PURPOSE The purpose of this study is to evaluate the radiation dose in patients undergoing liver angiographic procedure and verify the usefulness of different dose measurements to prevent deterministic effects. Gafchromic film, MicroMOSFET data and DIAMENTOR device of the X-ray system were used to characterize the examined interventional radiology (IR) procedure. MATERIALS AND METHODS A liver embolization procedure, the SIRT (Selective Internal Radiation Therapy), was investigated. The exposure parameters from the DIAMENTOR as well as patient and geometrical data were registered. Entrance skin dose map obtained using Gafchromic film (ESDGAF) in a standard phantom as well as in 12 patients were used to calculate the maximum skin dose (MSDGAF). MicroMOSFETs were used to assess ESD in relevant points/areas. Moreover, the maximum value of five MicroMOSFETs array, due to the extension of treated area and to the relative distance of 2-3 cm of two adjacent MicroMOSFETs, was useful to predict the MSD without interfering with the clinical practice. PCXMC vers.1.5 was used to calculate effective dose (E) and equivalent dose (H). RESULTS The mean dose-area product (DAPDIAMENTOR) for SIRT procedures was 166 Gycm2, although a wide range was observed. The mean MSDGAF for SIRT procedures was 1090 mGy, although a wide range was experienced. A correlation was found between the MSDGAF measured on a patient and the DAPDIAMENTOR value for liver embolizations. MOSFET and Gafchromic data were in agreement within 5% in homogeneous area and within 20% in high dose gradient regions. The mean equivalent dose in critical organs was 89.8 mSv for kidneys, 22.9 mSv for pancreas, 20.2 mSv for small intestine and 21.0 mSv for spleen. Whereas the mean E was 3.7 mSv (range: 0.5-13.7). CONCLUSIONS Gafchromic films result useful to study patient exposure and determine localization and amplitude of high dose skin areas to better predict the skin injuries. Then, DAPDIAMENTOR or MOSFET data could offer real-time methods, as on-line dose alert, to avoid any side effects during liver embolization with prolonged duration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Silibinin effects on the Viability of HepG2 (Human hepatocellular liver carcinoma) and HUVEC (Human Umbilical Vein Endothelial) cell lines

Human hepatocellular carcinoma is one of the most common recurrent malignancies, for as much as, there is no effective therapy. Silibinin, a widely used drug and supplement for various liver disorders, demonstrated anticancer effects against human hepatocellular carcinoma, human prostate adenocarcinoma cells, human breast carcinoma cells, human ectocervical carcinoma cells, and human colon canc...

متن کامل

Evaluation of Silibinin effects on the Viability of HepG2 (Human hepatocellular liver carcinoma) and HUVEC (Human Umbilical Vein Endothelial) cell lines

Human hepatocellular carcinoma is one of the most common recurrent malignancies, for as much as, there is no effective therapy. Silibinin, a widely used drug and supplement for various liver disorders, demonstrated anticancer effects against human hepatocellular carcinoma, human prostate adenocarcinoma cells, human breast carcinoma cells, human ectocervical carcinoma cells, and human colon canc...

متن کامل

Evaluation of serum AFP (α-fetoprotein) level in HBsAg carrier patients for diagnosis of hepatocellular carcinoma

Background: Hepatocellular carcinoma (HCC) is common all over the world as well as Iran. The incidence of HCC is higher in hepatitis B carriers and it is highly recommended to periodically screen these patients by serum alpha-fetoprotein (AFP) and liver ultrasound (US) every 6 months. We explore the diagnostic accuracy and the performance of (AFP) in cases of hepatitis B carriers as a scree...

متن کامل

Evaluation of Absorbed Dose of Critical Organ in Rando Phantom under Head, Abdomen and Pelvis Spiral CT Scan by Thermo Luminescent Dosimetery - TLD

Background & Objectives: Computed tomography (CT) represents 11% of all diagnostic radiology procedures but it contributes to almost 67% of the total effective dose to the human population. In head and neck CT which consist of 1/3 of total CT scans, other critical organs such as lenses and thyroid are in the radiation field. Also in the abdomen and pelvis scan, irradiation of ovaries is unavoid...

متن کامل

miR-26b enhances radiosensitivity of hepatocellular carcinoma cells by targeting EphA2

Objective(s): Although low-dose radiotherapy (RT) that involves low collateral damage is more suitable for hepatocellular carcinoma (HCC) than traditional high-dose RT, but to achieve satisfactory therapeutic effect with low-dose RT, it is necessary to sensitize HCC cells to irradiation. This study was aimed to determine whether radiosensitivity of HCC cells can be enhanced using miR-26b by tar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2013