Effect of intermittent subglottic secretion drainage on ventilator-associated pneumonia: A clinical trial
نویسندگان
چکیده
BACKGROUND Secretions contaminated with oral, nasal, and gastric bacteria accumulate in the subglottic space, above the endotracheal tube cuff. If these secretions are aspirated into lower airways, the intubated patient will be susceptible to ventilator-associated pneumonia (VAP). The aim of this study was to investigate the effect of inspiratory pause maneuver for intermittent subglottic secretions drainage (SSD) on the incidence of VAP in patients receiving mechanical ventilation. MATERIALS AND METHODS This randomized clinical trial was conducted in four intensive care units of educational hospital in Isfahan, Iran. A total of 76 adult patients intubated with a conventional endotracheal tube and connected to ventilators for more than 48 h were selected through convenient sampling and were randomly assigned to undergo intermittent SSD (n = 38) or not (n = 38). In this study, for SSD, we used inspiratory pause/hold key in the ventilators to hyperinflate the lungs. Pressure that produces with this maneuver could remove the secretions from the subglottic space. RESULTS VAP was found in 10 (26.3%) patients receiving SSD and in 18 (47.4%) patients in the control group (P = 0.04). CONCLUSIONS SSD using inspiratory pause during mechanical ventilation results in a significant reduction in VAP.
منابع مشابه
A randomized clinical trial of intermittent subglottic secretion drainage in patients receiving mechanical ventilation.
OBJECTIVE To study the effect of subglottic secretions drainage on the incidence of ventilator-associated pneumonia (VAP) in patients receiving mechanical ventilation. DESIGN A randomized clinical trial. SETTING A 12-bed general ICU. PATIENTS One hundred fifty patients with an expected duration of mechanical ventilation > 72 h were enrolled in the study. INTERVENTION Patients were rando...
متن کاملSubglottic secretion drainage for the prevention of ventilator-associated pneumonia: a systematic review and meta-analysis.
BACKGROUND AND PURPOSE Aspiration of secretions containing bacterial pathogens into the lower respiratory tract is the main cause of ventilator-associated pneumonia. Endotracheal tubes with subglottic secretion drainage can potentially reduce this and, therefore, the incidence of ventilator-associated pneumonia. New evidence on subglottic secretion drainage as a preventive measure for ventilato...
متن کاملIntermittent subglottic secretion drainage and ventilator-associated pneumonia.
RATIONALE Ventilator-associated pneumonia (VAP) causes substantial morbidity and mortality. The influence of subglottic secretion drainage (SSD) in preventing VAP remains controversial. OBJECTIVES To determine whether SSD reduces the overall incidence of microbiologically confirmed VAP. METHODS Randomized controlled clinical trial conducted at four French centers. A total of 333 adult patie...
متن کاملNumber needed to treat for subglottic secretion drainage technology as a ventilator-associated pneumonia prevention strategy
The number needed to treat can be calculated for ventilator-associated pneumonia reduction strategies such as subglottic secretion drainage technology based on previous work establishing its relative risk reduction. Assuming an incidence of 4%, employing subglottic secretion drainage in 33 patients will prevent one case of ventilator-associated pneumonia, and thus potentially 4 cases annually i...
متن کاملReview: subglottic secretion drainage reduces ventilator associated pneumonia.
Dezfulian C, Shojania K, Collard HR, et al. Subglottic secretion drainage for preventing ventilator-associated pneumonia: a metaanalysis. Am J Med 2005;118:11–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
متن کامل