In vivo prostate magnetic resonance imaging and magnetic resonance spectroscopy at 3 Tesla using a transceive pelvic phased array coil: preliminary results.
نویسندگان
چکیده
Magnetic resonance (MR) systems operating at 3 Telsa (T) and above have demonstrated considerable potential in human studies, offering improved signal-to-noise ratio and spectral resolution. However, because of radiofrequency limitations and concerns, and the lack of large volume body coils, most studies have been limited to the head. In this study we describe the design and construction of a transceive pelvic phased array coil with which MR images and spectra of the human prostate at 3 T have been obtained. Comparison with 1.5 T instruments with different hardware configurations is difficult; however, in a preliminary comparison the signal-to-noise ratio is improved in phantoms and humans when compared with a 1.5 T receive-only pelvic phased array coil, and high quality spectral resolution is demonstrated through the delineation of the citrate quadruplet in localized 1H prostate spectra. Higher fields offer the potential for MR prostate studies without the use of an endorectal coil.
منابع مشابه
Comparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer
PURPOSE Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil ...
متن کاملProstate cancer detection at repeat biopsy: can pelvic phased-array multiparametric MRI replace saturation biopsy?
AIM Magnetic resonance imaging (MRI) accuracy in prostate cancer (PCa) diagnosis in men submitted to saturation prostate biopsy (SPBx) was evaluated. MATERIALS AND METHODS From June 2011 to December 2012, 78 patients (median 63 years) underwent repeat SPBx (median 28 cores). Multiparametric MRI using a 3 Tesla pelvic phased-array coil was performed before SPBx and lesions suspicious for PCa w...
متن کاملMR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils
Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...
متن کاملAssessment of Radiotherapy Treatment in Cervical Cancer using Proton Magnetic Resonance Spectroscopy at 3 Tesla: a Pilot Study
Introduction: In vivo proton magnetic resonance spectroscopy (MRS) has proven to be helpful in both the initial diagnosis of cervical carcinoma and the subsequent surveillance after radiation therapy [1]. The characteristic metabolite pattern observed in malignant cervical disease is an elevation of choline signal, while decreasing choline level is representative of a successful treatment respo...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative radiology
دوره 38 7 شماره
صفحات -
تاریخ انتشار 2003