Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT

نویسندگان

  • Shozo Yamashita
  • Kunihiko Yokoyama
  • Masahisa Onoguchi
  • Haruki Yamamoto
  • Shigeaki Hiko
  • Akihiro Horita
  • Kenichi Nakajima
چکیده

OBJECTIVES Deep-inspiration breath-hold (DIBH) PET/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. METHODS In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. RESULTS In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. CONCLUSION DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deep-inspiration breath-hold PET/CT: clinical findings with a new technique for detection and characterization of thoracic lesions.

UNLABELLED Respiratory motion during PET/CT acquisition can cause misregistration and inaccuracies in calculation of standardized uptake values (SUVs). Our aim was to compare the detection and characterization of thoracic lesions on PET/CT with and without a deep-inspiration protocol. METHODS We studied 15 patients with suspected pulmonary lesions who underwent clinical PET/CT, followed by de...

متن کامل

Single 20-second acquisition of deep-inspiration breath-hold PET/CT: clinical feasibility for lung cancer.

UNLABELLED This study was designed to compare tumor (18)F-FDG uptake between a single 20-s acquisition of deep-inspiration breath-hold PET/CT and free-breathing PET/CT for lung cancer. METHODS Before the clinical study, a phantom study was performed to determine the optimum breath-hold time for the PET scan. We studied 47 patients with lung cancer who underwent free-breathing PET/CT with the ...

متن کامل

Deep Inspiration Breath Hold [(18)F]FDG PET-CT on 4-rings scanners in evaluating lung lesions: evidences from a phantom and a clinical study.

OBJECTIVE To investigate the clinical feasibility of a Deep Inspiration Breath Hold (DIBH) (18)F-FDG PET-CT acquisition in apnea and compare the results obtained between these acts of acquisition in apnea and in Free Breathing in the evaluation of lung lesions. MATERIAL AND METHODS A pre-clinical phantom study was performed to evaluate the shortest simulated DIBH time according to the minimum...

متن کامل

Breath-hold and free-breathing F-18-FDG-PET/CT in malignant melanoma—detection of additional tumoral foci and effects on quantitative parameters

During PET/CT acquisition, respiratory motion generates artifacts in the form of breath-related blurring, which may impair lesion detectability and diagnostic accuracy. This observational study was undertaken to verify whether breath-hold F-18-FDG-PET/CT (bhPET) detects additional foci compared to free-breathing PET/CT (fbPET) in cases of malignant melanoma, and to assess the impact of breath-h...

متن کامل

Improved attenuation correction via appropriate selection of respiratory-correlated PET data

PURPOSE We propose a respiratory-correlated PET data processing method (called "BH-CT-based") based on breath-hold CT acquisition to reduce the smearing effect and improve the attenuation correction. The resulting images are compared with the ungated PET images acquired using a standard, free-breathing clinical protocol. METHODS The BH-CT-based method consisted of a list-mode acquisition with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2014